INSTALLATION 

PERFORMANCE CHECK:

 

The following items should be checked before or within the first 30 days of operation by a qualified service technician. 

1. Check doors for proper alignment. 

2. Check door gaskets for wear and sealing ability. 

3. Check spray tubes or nozzles for cleanliness and/or leakage. 

4. Check all gauges, timers, valves and switches for proper operation. 

5. Visually check control compartment wiring for burned or loose connections. 

6. Check electrical load on elements for proper wattage. 

7. Be sure operators understand importance of proper cleaning and maintenance. 

NOTICE 

BE SURE ALL OWNERS MANUALS, WARRANTY INFORMATION, AND IMPORTANT 
PAPERS ARE GIVEN TO THE PROPER AUTHORITY. 

 

OPERATION 

THEORY OF OPERATION:

 

Compared to other steam cookers with complicated boilers, the RS-4E is a very simple machine. Immersion elements 
are installed on the left side of the cavity and when water covers the elements, water starts to boil and turn to steam. 
There is no pressure in this unit. 
The Steammaster RS-4E is designed to provide quick heat-up from a cold start. The RS-4E also utilizes an "Idle" system 
that conserves energy, while keeping the unit ready during low use periods. 
All equipment must be installed correctly to ensure proper operation and reliable service. Installation instructions must 
be followed by a qualified technician. 
Before you turn the unit on, be sure that you have: POWER to unit, WATER to unit, and an OPEN DRAIN. 

CONTROL OPERATIONS 

STARTUP:

 

1. Turn power switch on. Unit will fill quickly and begin heating. Unit will be up to operating temperature, ready to 

use, in approximately four (4) minutes. The "Ready" light will light up when the unit is ready to use. 

2. Start up may be initiated in any of the timer settings. "Man, Idle," or a "Set" time. 

A.  In "Idle" mode the unit will start up full power and go into Idle mode automatically when the ready light   

comes on. 

 

 

PAGE 7

 

Содержание RS-4E

Страница 1: ...ER MODEL RS 4E WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroug...

Страница 2: ...hen the terms and conditions of the Manufacturer s Limited Warranty will be rendered void and no warranty of any kind shall apply If the equipment has been changed altered modified or repaired by othe...

Страница 3: ...s to a hazard or unsafe practice which can result in personal injury or product or property damage This symbol refers to information that needs special attention or must be fully understood even thoug...

Страница 4: ...er pressure in cavity 0 34 gallons per minute at 45 p s i water pressure in condenser 0 42 total gallons per minute at 45 p s i IMPORTANT UNIT MUST BE LEVEL FOR PROPER OPERATION WARRANTY WILL BE VOIDE...

Страница 5: ...MUST COMPLY WITH CSA STANDARD C22 2 No 0 M1982 General Requirements Canadian Electrical Code Part II 109 M1981 Commercial Cooking Appliances NOTE Electrical diagrams are located inside right hand com...

Страница 6: ...cker inside panel Refer to Figure 2 WATER CONNECTION Connect cold water line 1 4 6mm NPT into female side of strainer located at right hand lower side of unit as you face the back of the steamer Water...

Страница 7: ...cal connections Do not locate the Model RS 4E adjacent to any high heat producing piece of equipment such as a range top griddle fryer etc that could allow radiant heat to raise the exterior temperatu...

Страница 8: ...and install as shown on drawing See Figure 1 4 If unit is to be installed on a counter top or other surface without using legs the unit must be sealed to the surface so as to prevent any water grease...

Страница 9: ...stalled on the left side of the cavity and when water covers the elements water starts to boil and turn to steam There is no pressure in this unit The Steammaster RS 4E is designed to provide quick he...

Страница 10: ...water and electricity during slow periods leave timer set to Idle mode P Opening the door during a Set timing run Pauses the timer Closing the door resumes timer with cooking time un affected P Timer...

Страница 11: ...Full Perforated Carrots Frozen Whole Baby 5 lbs 20 4 oz 12 Full Perforated Fresh 1 4 Inch Bias Cut 5 lbs 20 4 oz 12 Full Perforated Cabbage Green Cut Into Wedges 24 15 Full Perforated Red Cut Into We...

Страница 12: ...Noodles 2 lbs 32 2 oz 10 Full Perforated Uncooked Converted Rice 2 lbs 25 Full Perforated 2 Qts Water Oil Salt Navy Beans 2 Ibs Full Perforated Place beans in pan cover w 3 quarts hot tap water Steam...

Страница 13: ...20 to 30 minutes May be held on steam table After cooking chicken may be browned in Infra Red or Radiant Broiler Brush with melted margarine mixed with salad oil to give a golden brown color Use juic...

Страница 14: ...tal Never rub with a circular motion Soil and discoloration which do not respond to the above procedure can usually be removed by rubbing the surface with Scotch Brite scouring pads or stainless scour...

Страница 15: ...GUIDE Symptom Check or Replace No power Check circuit breaker No water Check water supply Heating elements will only operate for brief Clean and de lime steamer regular cycles and de lime light is ill...

Страница 16: ...sh and Electrical Characteristics as applicable For parts not listed consult a Southbend Authorized Parts Distributor or Southbend Authorized Service Agency Consult the Southbend Authorized Parts Serv...

Страница 17: ...t or part Should service be required at times which normally involve overtime or premium labor rates the owner shall be charged for the difference between normal service rates and such premium rates I...

Страница 18: ...s Cook Hold Convection Ovens Fryers Tilting Braising Pans Salamander Broilers Bake Roast Ovens Special Custom Equipment Cooker Mixer Kettles Cheese Melters Pizza Ovens Convection Steamers Floor Model...

Страница 19: ...nal professional service may be necessary to extend the useful life of this unit When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to...

Отзывы: