INSTALLATION
RS-4E
Electric connection - terminal block
Drain 1" NPT, leave open, do not connect to floor drain
Cold water inlet W, 30 p.s.i. min. - 60 p.s.i. max.
DIMENSIONS
( )=Millimeters
Width Heigh
DEPTH
DRAIN
WATER
ELECTRIC CONN
CRATE SIZE
Collie
Crated
MODEL
A
B
C
D
E
F
G
H
J
K
Width Dept
Heigh Volume Weight
RS-4E
16"
21"
24 3/8" 28 3/8" 8%"
1 1/4"
14 3/8" 1 1/4" 6 3/8"
2"
19
31
281/2" 10.13cf
112#
(406) (533)
(625)
(727)
(216)
(32)
(365)
(32)
(162)
(51)
.29cm
51kg
Internal Dimensions: 13 1/2 w x 22 d x 121/2 h
UTILITY INFORMATION:
ELECTRIC: One electric connection required.
MAX. AMPS PER LINE
TOTAL CONNECTED AMPS
1 PHASE
3 PHASE
208 V 60 Hz
47
28
220 V 50/60 Hz
44
27
240 V 60 Hz
40
24
380/220 V 50 Hz
26
15
415/240 V 50 Hz
24
14
480 V 60 Hz
20
12
WATER USAGE AT TIMED OR MANUAL COOKING:
0.08
gallons per minute at 45 p.s.i. water pressure in cavity. 0.34
gallons per minute at 45 p.s.i. water pressure in condenser. 0.42
total gallons per minute at 45 p.s.i.
IMPORTANT:
UNIT MUST BE LEVEL FOR PROPER
OPERATION. WARRANTY WILL BE VOIDED FOR IMPROPER
INSTALLATION.
"All units shipped 3 Phase. Field convertible to 1 Phase.
Circuit must be wired for maximum amps at required voltage.
WATER SPECIFICATIONS:
To meet warranty requirements, supply water must be as
follows:
Connection:
1/4" cold water
Pressure:
30 to 60 PSI
Total Dissolved Solids (TDS):
60PPM
Hardness:
2 grains or 35 PPM
PH Factor:
7.0 to 7.5
NOTICE
Southbend reserves the right to change
specifications and product design without notice.
Such revisions do not entitle the buyer to
corresponding changes, improvements,
additions or replacements for previously
purchased equipment.
NOTICE
Floor drain must be located outside the confines of the
equipment base.
NOTICE:
INTENDED FOR COMMERCIAL USE ONLY. NOT FOR HOUSEHOLD USE.
SPECIFICATIONS
Not for Scale
For Dimensional Purposes Only.