background image

I

NFRARED/

R

ADIANT 

C

OMPACT 

B

ROILER

 OWNER’S MANUAL 1186527 REV 6 (8/14)

 PAGE 6

    

OF 21

NOTICE

These installation procedures must be followed by qualified personnel or warranty will be void.

Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc. 

states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation 

requirements for equipment. Therefore, installations should comply with all local codes.

The installation must conform with local codes, or in the absence of local codes, with the 

National Fuel Gas Code, 

ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1

, or the 

Propane Installation Code CAN/CGA-B149.2, 

as applicable, including:

1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any         

    pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa) or 35 mbar (14” W.C).

2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve   

    during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45   

    kPa) 35 mbar (14” W.C).

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE

All containers should be examined for damage before and during unloading. The freight carrier has assumed 

responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a claim 

must be made with the delivering carrier.

Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be signed

by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier can supply 

the necessary forms.

A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not 

apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all 

contents plus all packing material.

For each section, do the following:

1.  Cut the banding straps and remove the corrugated cardboard surrounding the broiler. If legs were shipped in   

     the same container, set them aside for installation in later steps of this procedure. Do not remove any tags or labels   

     attached to the broiler until the broiler is installed and working properly.
2.  Cut the banding strap holding the broiler to the wooden skid.
3.  If installing the broiler over a range, go to Step 2a.

     If installing the broiler on a wall, go to Step 2b.

     If installing the broiler on legs for countertop use, go to Step 2c.

S

TEP 

1

U

NPACKING

I

NSTALLATION

NOTICE

EXHAUST FANS AND CANOPIES: 

It is recommended that the Southbend equipment be installed under a ventilation 

hood. Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsibility. Any problem 

due to improper ventilation will not be covered by warranty.

NOTICE

In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation hoods 

shall comply with 248 CMR interlocking requirements.

I

NSTALLATION

Содержание P36-RAD

Страница 1: ..._ Serial ___________________________ Date Purchased _____________________ 1100 Old Honeycutt Road Fuquay Varina North Carolina 27526 USA www southbendnc com WARNING Improper installation adjustment al...

Страница 2: ...in a prominent location detailed instructions to be followed in the event the operator smells gas Obtain the instructions from the local gas supplier WARNING EXPLOSION AND ASPHYXIATION HAZARD In the e...

Страница 3: ...stallation 6 Operation 12 Cleaning 15 Troubleshooting 17 Read these instructions carefully before attempting installation Installation and initial startup should be performed by a qualified installer...

Страница 4: ...FICATIONS CLEARANCES WARNING Improper ventilation can result in personal injury or death Ventilation which fails to properly remove flue products can cause headaches drowsiness nausea or could result...

Страница 5: ...usted for the type of gas specified by the purchaser which is indicated on the serial plate see Figure 1 Connect the broiler ONLY to the type of gas for which it is configured and adjusted Sectional r...

Страница 6: ...ncealed a claim must be made with the delivering carrier Apparent damage or loss must be noted on the freight bill at the time of delivery The freight bill must then be signed by the carrier represent...

Страница 7: ...front edge of the flue riser If necessary move the broiler left or right so that the holes in the top of the broiler hook line up with the holes in the top of the flue riser then secure the broiler ho...

Страница 8: ...EP 2B MOUNT ON WALL 3 It may be more convenient to prepare the gas supply line before the broiler is mounted on the wall bracket If so install the supply line and connector now but do not yet attach i...

Страница 9: ...equire field piping Restaurant range mounted broilers will connect to the existing regulator on the restaurant range oven base Broilers mounted on the flue riser of a range will have a 3 8 rear gas co...

Страница 10: ...supply to the inlet at right rear corner using the external regulator shipped with the unit 4 For flue riser mounted installation use the supplied regulator Connect gas supply from broiler which exte...

Страница 11: ...ct flame appearance and height at both the HIGH and LOW settings When the burners ignite a blue haze type flame will cover the surface of the ceramics but will gradually disappear within two minutes W...

Страница 12: ...that provide better quality products in about one half the usual broiling time and with less gas input than ordinary broilers Very little energy is wasted in heating secondary surfaces which is neces...

Страница 13: ...t the constant burning pilots located near the front of the broiler burners unless the pilots are already lit See page 10 for directions on how to light the pilots 2 If necessary pull out and empty th...

Страница 14: ...he control valves on the front of the broiler to OFF 2 Turn on the gas supply to the broiler if not already on 3 Light the pilots To light the pilots on a broiler WITH the flame failure option do the...

Страница 15: ...the bottom grease drawer and clean it 7 Clean all parts of the raising and lowering frame 8 Lubricate bearings with cooking oil helps to extend the life of the bearings 9 Reassemble broiling rack mec...

Страница 16: ...ds or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the finish NEVER USE A WIRE BRUSH STEEL SCOURING PADS EX...

Страница 17: ...s in operation at initial installation check type of gas and manifold pressure and compare with information listed on the serial plate TROUBLESHOOTING Problem Look for 1 Not enough heat Low pressure i...

Страница 18: ...s manual for guidance ADJUSTMENT OF BROILER PILOTS The pilots are adjusted at the factory If later the pilots are over adjusted to the point where the flame is leaving its port or blowing off the resu...

Страница 19: ...3 Turn the broiler control knob to HIGH and with the burners lit check the manifold pressure The pressure should be 4 W C for natural gas or 10 W C for propane gas 4 If necessary adjust the pressure...

Страница 20: ...INFRARED RADIANT COMPACT BROILER OWNER S MANUAL 1186527 REV 6 8 14 PAGE 20 OF 21 Notes...

Страница 21: ...ent parts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid...

Отзывы: