background image

PARTS 

ELECTRONIC IGNITION UNITS ONLY 

KEY NO. 

PART NO.  DESCRIPTION 

PE-141 

6-PIN SOCKET (1165698) 

PE-143 

FEMALE PIN FOR 1165698 (1165712) 

1166562 

THERMOSTAT 

PP-688 

PRESSURE SWITCH (1166490) 

PP-637 

PRESSURE GAUGE (1166489) 

1167910 

COPPER TUBE 

PP-252 

ELBOW (1166472) 

PP-251 

TEE (1166471) 

1167909 

COPPER TUBE (Vessel To Pressure Switch) 

10 

PP-427 

TEE 

11 

PA-016 

FLAME SWITCH (1166479) 

12 

1167894 

COMPLETE SIGHT GLASS ASSEMBLY 
FOR 20 GALLON 

12 

1167895 

COMPLETE SIGHT GLASS ASSEMBLY 
FOR 40 GALLON 

12 

1167896 

COMPLETE SIGHT GLASS ASSEMBLY 
FOR 60 GALLON 

 
 

 
 

(Assembly Includes All Fittings & Tubes)

 

13 

1167911 

GLASS & RUBBER WASHER FOR 
SERVICE ONLY 

14 

PE-140 

6-PIN PLUG - FEMALE (1165687) 

15 

PE-142 

MALE PIN FOR 1165697 (1165711) 

16 

PA-006 

COMBINATION CONTROL - NATURAL GAS 
(1164810) 

 
 

 
 

(Knob Not Separate) 

16 

PA-007 

COMBINATION CONTROL - PROPANE 
GAS (1164811) 

 
 

 
 

(Knot) Not Separate) 

17 

1166492 

FRONT SHIELD FOR 20 OR 40 GALLON 

17 

1166561 

FRONT SHIELD FOR 60 GALLON 

18 

1166527 

MANIFOLD WELD ASSEMBLY 

19 

PM-099 

SPRING FOR CONTROL (1160408) 

20 

1166574 

DOOR HINGE ROD ASSEMBLY 

 

 

 

 

 

KEY NO.  PART NO.  DESCRIPTION 

1166562 

THERMOSTAT 

PE-146 

TIMERS (1166480) 

PE-148 

LOW WATER CUT OFF (1166454) 

PA-001 

SPARK IGNITER (1164809) 

PE-133 

RELAY WITHOUT COVER (1167003) 

PE-134 

RELAY SOCKET (1161526) 

PP-254 

FITTING (1166473) 

1167797 

TUBE 

PA-006 

GAS CONTROL (Elect. Ignition) - NATURAL 
GAS (1164810) 

PA-007 

GAS CONTROL (Elect. Ignition) - PROPANE 
GAS (1164811) 

10 

PP-253 

FITTING (P-9158) 

STATIONARY GAS STEAM KETTLES

 

SECTION FOUR — PARTS

 

PAGE 3

 

Содержание KSLG-20

Страница 1: ...g equipment then the terms and conditions of the Manufacturer s Limited Warranty will be rendered void and no warranty of any kind shall apply If the equipment has been changed altered modified or rep...

Страница 2: ...o Stationary Gas Kettles with a standing pilot or electronic ignition You can determine if your unit is equipped with electronic ignition by examining the Model No on the serial plate The serial plate...

Страница 3: ...TU One 1 male connection for location see drawing above NATURAL PROPANE Required operating pressure Natural Gas 4 W C Propane Gas 10 W C GAS KSLG 40 Total 100 000 BTU One 1 male connection for locatio...

Страница 4: ...ve the vent opening at the top of the unit CLEARANCES Adequate clearance must be provided in aisle and at the side and back Adequate clearances for air openings into the combustion chamber must be pro...

Страница 5: ...It is recommended that an individual manual shutoff valve be installed in the gas supply line to the unit Use pipe joint compound which is suitable for use with LP gas on all threaded connections Tes...

Страница 6: ...s and ground wire through the hole in the cover with a strain relief fitting Connect wires to the primary transformer terminals as required by your power supply voltage See wiring diagram at the rear...

Страница 7: ...consequential or special damages of any nature that may arise in connection with such product or part Should service be required at times which normally involve overtime or premium labor rates the own...

Страница 8: ...the unit should be open Remove shield which fits over the burners for access to the pilot which is located on the right side of the left burner approximately 6 into the combustion chamber Depress dia...

Страница 9: ...erous times after each 3 minute lockout period until the air is purged from the gas line Shut Down Standby 1 a Place power on switch in off position Complete a Place power on switch in off position b...

Страница 10: ...standing pilots this light may be on without the burners being on if the pilot is extinguished See lighting instructions Amber Low Water Light 3 All kettles are supplied with sufficient distilled wate...

Страница 11: ...n to restart the pilot lighting sequence once lockout has occurred If the pilot blows out during operation the unit will go through the same sequence to re ignite itself Once the pilot is ignited anot...

Страница 12: ...llect dirt more rapidly and become more difficult to clean Marring also increases the possibility of corrosive attack Refinish ing may then be required TO REMOVE HEAT TINT Darkened areas sometimes app...

Страница 13: ...ation control valve located just behind the lower front access door It is located on the center left side of the control see wiring diagram or pictures just below the large slotted screw head Remove t...

Страница 14: ...repeat this procedure 5 If pressure in kettle is below 40 psi increase setting of pressure switch cool kettle completely by running cold water through it and repeat this procedure 6 To obtain access t...

Страница 15: ...Gallons RE ESTABLISHING VACUUM With the kettle completely cold a vacuum of 25 to 30 inches mercury column M C should be main tained as indicated by the pressure gauge on the front control panel If at...

Страница 16: ...rollout on ignition carboning Incorrect orifice size Propane gas on natural Low gas pressure Incorrect orifice size Faulty regulator in gas control Unit slow to preheat and slow to recover Loss of vac...

Страница 17: ...as control Natural gas unit on propane Excessive gas pressure Incorrect orifice size Excessive flame rollout on ignition carboning Faulty regulator in gas control Propane gas on natural Low gas pressu...

Страница 18: ...SERVICE STATIONARY GAS STEAM KETTLES SECTION THREE SERVICE PAGE 6 Litho in U S A 5 88...

Страница 19: ...SERVICE STATIONARY GAS STEAM KETTLES SECTION THREE SERVICE PAGE 7...

Страница 20: ...ristics as applicable For parts not listed consult a Southbend Authorized Parts Distributor or Southbend Authorized Service Agency If necessary please consult Southbend Parts Department for assistance...

Страница 21: ...DING PILOT TUBES FOR 40 GALLON 17 1167916 STANDING PILOT TUBES FOR 60 GALLON 18 PE 137 COMBINATION GAS CONTROL UNITROL NATURAL GAS 1164804 1053900 PLATE SPRING ONLY NAT GAS FOR CONTROL 18 PE 138 COMBI...

Страница 22: ...PE 140 6 PIN PLUG FEMALE 1165687 15 PE 142 MALE PIN FOR 1165697 1165711 16 PA 006 COMBINATION CONTROL NATURAL GAS 1164810 Knob Not Separate 16 PA 007 COMBINATION CONTROL PROPANE GAS 1164811 Knot Not S...

Страница 23: ...1 1166457 13 PA 014 PROPANE GAS ORIFICE 60 GALLON 39 1166458 14 PH 075 MOUNTING BOLT 1167908 MISCELLANEOUS PARTS NOT SHOWN IN PHOTOS KSLG PART NO DESCRIPTION 20 20E 40 40E 60 60E 1166507 LID w HANDLE...

Страница 24: ...919 552 9798 800 348 2558 Convection ovens Cook hold convection ovens Bake roast ovens Pizza ovens Ranges Fryers Special custom equipment Convection steamers Steam kettles Tilting braising pans Cooker...

Страница 25: ...essional service may be necessary to extend the useful life of this unit When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to the mode...

Отзывы: