TROUBLE SHOOTING:
ELECTRONIC IGNITION UNITS:
Problem:
Look For:
-
Power switch is off.
-
Unit not plugged in.
-
Main power supply off.
-
Fuse in unit blown.
-
Bad purge timer.
Unit will not come on
-
Bad spark igniter.
-
Lockout has occurred.
-
Thermostat not on.
-
Gas control valve off.
-
Main gas supply off.
-
Low water.
-
Bad thermostat.
-
Bad pressure switch.
-
Bad gas control valve.
-
Bad flame switch.
-
Flame switch bulb not in pilot.
-
Relay unplugged or faulty.
Unit will turn on electrically but will not heat
-
Faulty pilot solenoid in gas control.
-
Natural gas unit on propane.
-
Excessive gas pressure.
-
Incorrect orifice size.
Excessive flame rollout on ignition, carboning
-
Faulty regulator in gas control.
-
Propane gas on natural.
-
Low gas pressure.
-
Incorrect orifice sizes.
-
Loss of vacuum.
Unit slow to preheat and slow to recover
-
Faulty regulator in gas control.
-
Pilot gas adjusted too low.
-
Excessive draft condition.
-
Excessive steam around bottom of unit during operation or
cleaning.
-
Faulty flame switch.
-
Flame switch bulb not mounted to pilot correctly.
-
Faulty lockout time.
-
Faulty purge timer.
-
Faulty spark igniter.
Unit continuously locks out
-
Faulty pilot solenoid in gas control.
STATIONARY GAS STEAM KETTLES
SECTION THREE — SERVICE
PAGE 5
SERVICE