![Southbend GC-2S Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/southbend/gc-2s/gc-2s_owners-manual_1336833005.webp)
INSTALLATION
&
SERVICE CONNECTIONS
MODELS:GC-2, GC-3
SECTION 1: GDA-2 & GDH-2
INSTALLATION INSTRUCTIONS
Cooker location should have an exhaust system provided directly above the appliance to exhaust
combustion gases generated by the Gas Boiler.
APPLIANCE IS INTENDED FOR USE ON NONCOMBUSTIBLF- FLOORS. MINIMUM CLEARANCE
FROM COMBUSTIBLE CONSTRUCTION, 3" ON SIDES AND 4" FROM BACK.
Ascertain that adequate clearance of left side of appliance is available for servicing components
contained in Cooker Control Enclosure.
Set Cooker in place and level appliance using spirit level. Mark hole locations on floor through anchoring
holes provided in flanged adjustable feet.
Remove appliance and drill holes into locations marked on floor and insert proper anchoring devices.
Set Cooker back in proper position.
Re-level the appliance, leveling the unit left to right and front to back. Appliance should be elevated on
the right 1/16" to 1/8" to assure proper compartment drainage.
Bolt and anchor appliance security to the floor. Seal bolts and flanged feet with Silastic or equivalent
compound.
SERVICE CONNECTIONS
Make service connections as indicated in LEGEND (Fig. 1).
GAS INSTALLATION TO CONFORM TO LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES
TO NATIONAL FUEL GAS CODE - ANSI Z223.1 - 1984. FURTHER NOTE THAT:
1. THE APPLIANCE AND ITS INDIVIDUAL SHUT-OFF VALVE MUST BE DISCONNECTED FROM
THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM
AT TEST PRESSURES IN EXCESS OF 1/2 PSIG (3.45kPa).
2. THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING
ITS INDIVIDUAL MANUAL SHUT-OFF VALVE DURING ANY PRESSURE TESTING OF THE GAS
SUPPLY PIPING SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG
(3.45kPa).
ELECTRICAL GROUNDING MUST BE PROVIDED IN ACCORDANCE WITH LOCAL CODES. OR IN
THE ABSENCE OF LOCAL CODES. WITH THE NATIONAL ELECTRIC CODE, ANS1/NFPA 70 -
1984.
3
Содержание GC-2S
Страница 10: ...PERIODIC MAINTENANCE SECTION 4 MODELS GC 2 6C 3 SIDE VIEW 8 FIG 2...
Страница 14: ...PERIODIC MAINTENANCE MODELS GC 2 GC 3 SECTION 4 FIG 3 12 EXHAUST TO DRAIN STEAM IN...
Страница 26: ...PARTS LIST SECTION 7 COMPARTMENT DOOR ASSEMBLY FIG 4 23 Parts List...
Страница 28: ...PARTS LIST SECTION 7 COOKER ASSEMBLY FIG 5 25...
Страница 30: ...PARTS LIST SECTION 7 COOKER CONTROLS FIG 6 27...
Страница 32: ...PARTS LIST MODELS GC 2 GC 3 SECTION 7 CABINET FIG 7 29...
Страница 34: ...PARTS LIST SECTION 7 MODELS GC 2 GC 3 GENERATOR CONTROL BOX ASSEMBLY FIG 8 31 Parts List...
Страница 36: ...PARTS LIST SECTION 7 MODELS GC 2 GC 3 GENERATOR ASSEMBLY FIG 9 33...
Страница 38: ...PARTS LIST 35 SECTION 7 MODELS GC 2 GC 3 GAS BOILER ASSEMBLY FIG 10 Boiler rated 170 000 BTU HR...
Страница 40: ...WIRING DIAGRAM SECTION 8 MODELS GC 2 GC 3 37...
Страница 41: ...WIRING DIAGRAM SECTION 8 MODELS GC 2 GC 3 38...
Страница 42: ...WIRING DIAGRAM MODELS EDA 2 SCDA 2 GDA 2 DDA 2 SECTION 9 SUPPLEMENT...