PERIODIC MAINTENANCE
SECTION 4: MODELS: GC-2
& GC-3
Item F: A Steam Solenoid Valve is provided for each compartment and will open when energized to
allow steam entry into the compartment. This valve will remain de-energized and closed if the Timer
reads ' 0' and/or the Operating Handle is in the released position.
Item G: An Exhaust Solenoid valve is provided for each compartment and operates in reverse to Item
F; that is, it will close when energized thus sealing the steam, provided by the Steam Valve, within the
compartment.
ANY FOREIGN MATERIAL, OTHER THAN STEAM OR WATER,
SHOULD NOT BE ALLOWED TO EXHAUST THROUGH THIS VALVE.
AFTER OPERATION WIPE AND REMOVE FOOD OR ANY OTHER
PARTICLES FROM EACH COMPARTMENT BOTTOM.
A stainless steel strainer is provided in each compartment just ahead of the exhaust port as a
protective device for this valve. Remove, clean and replace if excessive food and/or dirt accumulation
is evident.
IF PARTICULARLY GREASY FOODS HAVE BEEN COOKED IN THE
COMPARTMENT, DEPOSITS MAY ACCUMULATE IN EXHAUST
VALVES AND MUST BE REMOVED BY CLOSING DOOR, SEALING
COMPARTMENT. SETTING TIMER AND AT FREQUENT INTERVALS
PULL OUT AND RELEASE OPERATING HANDLE TO BLOW STEAM
THROUGH VALVE AND DISSOLVE GREASE.
Item H: A Pressure Gauge is fastened to the bottom face of the Cooker Control Panel. It is plumbed to
sense pressure in the Steam Header. When compartments are inactive, it should read approximately 6
p.s.i. but will fluctuate between 4 ½ to 6 p.s.i. during the cooking cycle. Pressure above 6 p.s.i.
indicates that Pressure Regulating Valve is set too high and may set off Pressure Relief Valve (Item
E).
Item I: Flue Stack Assembly is located directly behind Cooker (See Page
29, Parts No. 7 & 8) and
provides for exhaust of combustion gases.
AT LEAST TWICE A YEAR EXAMINE THAT INTERIOR OF FLUE STACK
IS CLEAN. IF ACCUMULATION OF DIRT AND/OR SOOT IS APPARENT,
THE STACK COVER AND FLUE STACK MUST BE REMOVED AND
CLEANED. ALSO PORTION OF FLUE EXTENDING BELOW CABINET
SURFACE TO BOILER MUST BE CLEANED.
Содержание GC-2S
Страница 10: ...PERIODIC MAINTENANCE SECTION 4 MODELS GC 2 6C 3 SIDE VIEW 8 FIG 2...
Страница 14: ...PERIODIC MAINTENANCE MODELS GC 2 GC 3 SECTION 4 FIG 3 12 EXHAUST TO DRAIN STEAM IN...
Страница 26: ...PARTS LIST SECTION 7 COMPARTMENT DOOR ASSEMBLY FIG 4 23 Parts List...
Страница 28: ...PARTS LIST SECTION 7 COOKER ASSEMBLY FIG 5 25...
Страница 30: ...PARTS LIST SECTION 7 COOKER CONTROLS FIG 6 27...
Страница 32: ...PARTS LIST MODELS GC 2 GC 3 SECTION 7 CABINET FIG 7 29...
Страница 34: ...PARTS LIST SECTION 7 MODELS GC 2 GC 3 GENERATOR CONTROL BOX ASSEMBLY FIG 8 31 Parts List...
Страница 36: ...PARTS LIST SECTION 7 MODELS GC 2 GC 3 GENERATOR ASSEMBLY FIG 9 33...
Страница 38: ...PARTS LIST 35 SECTION 7 MODELS GC 2 GC 3 GAS BOILER ASSEMBLY FIG 10 Boiler rated 170 000 BTU HR...
Страница 40: ...WIRING DIAGRAM SECTION 8 MODELS GC 2 GC 3 37...
Страница 41: ...WIRING DIAGRAM SECTION 8 MODELS GC 2 GC 3 38...
Страница 42: ...WIRING DIAGRAM MODELS EDA 2 SCDA 2 GDA 2 DDA 2 SECTION 9 SUPPLEMENT...