background image

IMPORTANT 

FOR FUTURE REFERENCE

 

Please complete this informa-

 

tion and retain this manual for

 

the life of the equipment.

 

MODEL 

#

 

SERIAL #

 

DATE PURCHASED

 

 

OWNER'S MANUAL

 

INSTALLATION 

USER'S GUIDE 

SERVICE  

PARTS 

SECTIONAL RANGE 

FRONT MANIFOLD 

BATTERY TYPE 

(See Section 1, Page 2 for Models)

 

These instructions should be read thoroughly before attempting installation. Installation and Start Up 

should be performed by a qualified service technician. The Manufacturer, Southbend (1100 Old 

Honeycutt Rd., Fuquay-Varina, North Carolina 27526), informs you that unless the installation 

instructions for the above described Southbend product are followed and performed by a qualified 

service technician, (a person experienced in and knowledgeable concerning the  installation of 

commercial gas and/or electrical cooking equipment) then the terms and conditions of the 

Manufacturer's Limited Warranty will be rendered void and no warranty of any kind shall apply. 

If the equipment has been changed, altered, modified or  repaired by other than a qualified service 

technician during or after the 12-month limited warranty period, then the manufacturer shall not be liable 

for any incidental or consequential damages to any person or to any property which may result from the 

use of the equipment thereafter. Some States do not allow the exclusion or limitation of incidental or 

consequential damages, so the above limitation or exclusion thereto may not apply to you. 
In the event you have any questions concerning the installation, use. care, or service of the product, 

write Customer Service Department, Southbend, 1100 Old Honeycutt Rd., Fuquay-Varina, North 

Carolina 27526. 

WARNING: Improper installation, adjustment, alteration,

 

service or maintenance can cause property damage, injury or

 

death. Read the installation, operating and maintenance

 

instructions thoroughly before installing or servicing this

 

equipment.

 

 

 

 

$6.00

 

SECTIONAL RANGES 

(Manual Section SR)

 

Содержание 121C-0

Страница 1: ... Limited Warranty will be rendered void and no warranty of any kind shall apply If the equipment has been changed altered modified or repaired by other than a qualified service technician during or after the 12 month limited warranty period then the manufacturer shall not be liable for any incidental or consequential damages to any person or to any property which may result from the use of the equ...

Страница 2: ...For Sectional Battery Assembly Instruction See ATTENTION INSTALLER MANUAL Part No 1165403 1 SECTION TWO USER S GUIDE Warranty 1 Operation 2 Cooking Hints 6 Maintenance 8 SECTION THREE SERVICE Adjustments 1 Service 6 Troubleshooting 6 Schematic Drawings 9 SECTION FOUR PARTS Parts List 1 CAUTION POST IN PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED THIS INF...

Страница 3: ... G Total H I Ck Top J K L M N 36 Deep Standard Oven Unit 1364 32 36 3175 33 3 23 36 6 30 33 75 33 5 36 Deep Convention Oven Unit CO 1364 32 36 37 4 2 min 31 75 33 3 23 36 6 30 33 75 33 5 2 21 42 Deep Standard Oven Unit 1424 32 42 3175 39 3 23 36 6 30 33 75 39 5 42 Deep Convention Oven Unit CO 1424 32 42 4 3175 39 3 23 36 6 30 33 75 39 5 2 21 SECTIONAL RANGES SECTION ONE INSTALLATION PAGE 1 ...

Страница 4: ...1 164D 1 Grate Top 2 Burners Half Section 124D 1 1366C 1 1 2 Grate Top 1 2 Fry Top 1426C 1 1367C 1 1 2 Uniform Top 1 2 Fry Top 1427C 1 1364DHT 1 2 1 2 Grate Tops 2 1 2 Uniform Tops 1424DHT 1 164DHT 1 1 1 2 Grate Top 1 1 2 Uniform Top 124DHT 1 163D 1 2 Burner 12 wide Module 1363 Match RANGES WITHOUT OVEN OR CABINET BASE 136C 0 Graduated Heat Top 142C 0 1361C 0 Fry Top 1421C 0 1362C 0 Uniform Heat T...

Страница 5: ...ode Code CAN CGA B149 2 Propane Installation Code An adequate gas supply is imperative Undersized or low pressure lines restrict the volume of gas required for satisfactory performance A steady supply pressure between 7 W C and 8 W C for natural gas and 11 W C and 12 W C for propane gas is recommended With all units operating simultaneously the manifold pressure on all units should not show any ap...

Страница 6: ...IMUM CLEARANCE OF TWO INCHES MUST BE ALLOWED BEHIND THE MOTOR AND ANY REAR NON COMBUSTIBLE ENCLOSURE CARE MUST BE TAKEN TO PROVIDE ADEQUATE AIR CIRCULATION TO PREVENT THE MOTOR FROM OVERHEATING NO ADDITIONAL CLEARANCE FROM THE SIDES AND BACK IS REQUIRED FOR SERVICE AS THE UNITS ARE SERVICEABLE FROM THE FRONT LEGS OR OPTIONAL CASTERS 1 A set of legs or casters are packed in the unit A threaded rece...

Страница 7: ...PLIANCE IS MOVED TO ITS ORIGINALLY INSTALLED POSITION GAS CONNECTION On all threaded connections the pipe joint compound must be approved for used with natural and LP gas I INDIVIDUAL UNITS 1 Remove valve panel 2 Use a long spirit level four ways across the front top rail and rear collar plate and along each edge 3 A For units without a rear gas connections connect the gas supply to the right or l...

Страница 8: ...ective unit 3 Bring up adjacent units level by same method and by using the center unit as reference Match front rails and rear collar plates When battery is set on a masonry base and legs are not used shims may be used Special attention should be given to Fry Top ranges to allow proper drainage on griddles 4 Where Spreader Plates are installed refer to Sectional Battery Component Assembly Instruc...

Страница 9: ...h on to unit allowing studs C to enter holes in the shelf bracket Secure shelf bracket B with nuts and lock washers that were removed in instruction No 2 4 The flue riser extension D is packed with unit Slide flue riser extension over the flue E protruding through the center opening of the collar plate F Replace panel A On models where flue E extends above collar plate approximately 4 flue extensi...

Страница 10: ...les using an 11 64 171 dia drill and secure with 10 x 1 2 slotted truss head sheet metal screws FIG 3 FLAT TYPE FRONT FILLER 1692 Black 1692SS Stainless Steel APPLICATION Fryer or Cabinet Base Unit battened to a Fryer or Cabinet Based Unit MOUNTING PROCEDURE Align filler equally spaced over each unit Drill securing holes with a 38 drill using pre punched holes in filler as a guide and secure with ...

Страница 11: ... Unit on right MOUNTING PROCEDURE 1 RIGHT SIDE OF THE CONVECTION OVEN BASE UNIT AT CONTROL PANEL Loosen the two screws on the right side of the front filler panel Align the two slots in the front filler with the two screws Push filler in until it is flush with the front of the front filler panel and retighten the two screws 2 For Standard Oven Base Units and Convection Oven Base Units being batter...

Страница 12: ... and top 2 Using the pre punched holes in the end trim as a guide drill 3 1 8 125 dia holes and secure with 3 8 x 1 2 sheet metal screws WARNING TUBULAR GAS LINES ARE LOCATED ON THE SIDES OF THE OVEN BASE UNITS BEHIND THE END TRIM SECURING SCREW AREA IF HOLES NEED TO BE DRILLED CARE MUST BE TAKEN AND INSPECTION MADE TO INSURE THAT GAS LINES ARE NOT PUNCTURED NOTE Fryers Spreader Cabinets Half Sect...

Страница 13: ...4486 18 POT FRYER BROILER OR FRY TOP RANGE OR CB 1165280 14 POT FRYER 14 POT FRYER 1165279 18 POT FRYER 18 POT FRYER 1165269 14 POT FRYER 18 POT FRYER 1165270 18 POT FRYER 14 POT FRYER 1165267 DRAIN CABINET 14 POT FRYER 1165268 14 POT FRYER DRAIN CABINET 1165271 DRAIN CABINET 18 POT FRYER 1165272 18 POT FRYER DRAIN CABINET 1165266 ANY RANGE except Fry Top DRAIN CABINET w 14 Fryer on Right of it 11...

Страница 14: ... not be liable for consequential or special damages of any nature that may arise in connection with such product or part Should service be required at times which normally involve overtime or premium labor rates the owner shall be charged for the difference between normal service rates and such premium rates In all circumstances a maximum of one hundred miles in travel and two and one half hours 2...

Страница 15: ...quire time to bleed air from system before pilot will become steady The pilot flame should impinge on the bulb to cause it to glow red If flame is too long and soft bulb may be in hollow part of flame and will not glow Hold red button allowing pilot to burn approximately 45 seconds until tip of bulb glows red and then release button If pilot does not remain ignited wait 5 minutes and repeat proced...

Страница 16: ...s sensing point It will run continuously until the temperature inside of the control box drops to 135 degrees F The cooling blower operates independent of the power switch therefore eliminating any control damaging residual heat rise after the unit has been completely shut down For further protection of the control box controls if the cooling blower should happen to fail the oven burner and the ov...

Страница 17: ...OCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE 2 STANDBY SHUTDOWN Place the power switch in the OFF position 3 COMPLETE SHUTDOWN Place the power switch in the OFF position and place the oven gas supply line shutoff valve in the closed position 4 RELIGHTING Place the oven gas supply line shutoff valve in the open position and place the power switch in the ON position SPARK IGNITER FAILURE In the even...

Страница 18: ...me Turn off burner 6 Lower griddle carefully into position taking extreme care that capillary tubes are coiled into manifold compartment NEVER leave any part of the capillary tube in the burner compartment 7 Observe burner flame through slots in grease trough with thermostat dial at maximum for five minutes Then turn dial to its lowest setting and observe by pass flame which should be a 1 8 minimu...

Страница 19: ...8 OZ SIZE Wash and wrap in potato foil Place 30 potatoes on 18 x 24 bun pan 3 pans per load Bake in 400 degree F oven for 1 hour G TOP ROUND OF BEEF NO 168 Set oven at 250 degrees F Place trimmed roast on pan For 14 16 pounds 140 degrees rare 14 minutes pound 150 degrees medium 16 minutes pound 160 degrees well done 17 1 2 minutes pound SUGGESTIONS Convection Type Oven If cakes are dark on the sid...

Страница 20: ...tatoes 8 oz 60 400 3 30 wrapped Pre blanched potatoes frozen 16 400 3 5 lb Fish portions pre cooked breaded 3 oz 16 400 3 32 Macaroni cheese 6 lb 40 temp 45 400 3 2 6 lbs Lasagna w meat sauce 6 lb 40 temp 60 350 3 2 6 lbs Lasagna w meat sauce 6 lb frozen 75 350 3 2 6 lbs Salisbury steak w gravy 6 lb 40 temp 45 400 3 2 6 lbs Top round of beef No 168 14 lb rare 140 internal 14 min lb 250 1 1 2 14 lb...

Страница 21: ...UTION WHENEVER SERVICING OR CLEANING THE OVEN THE MAIN POWER SUPPLIES TO THE OVEN MUST BE DISCONNECTED Oven bottom and oven door lining are finished with a porcelain enamel coating which encourages frequent cleaning Spill overs should be cleaned from the bottom or the door lining as soon as possible to prevent carbonizing and a burnt on condition Usually a soap or detergent solution is strong enou...

Страница 22: ...burner must be free from any spillage residue or other obstructions The flash tubes must be clean and properly aligned with the piloting housing to insure good top burner ignition Remove and clean drip tray which is below the burners daily BLACK BAKED ENAMEL Allow unit to cool somewhat after use and wash exterior with a hot mild detergent or soap solution particularly clean off all grease deposits...

Страница 23: ...low the oven door see Diagram 2 Remove the front panel to gain accessibility The pilot flame is properly adjusted when it is just large enough to maintain a glowing red color of the flame switch capillary bulb TOP SECTION PILOTS All top section pilots are adjustable by turning the slotted screw on the pilot valve located at the manifold BURNER HIGH ADJUSTMENT All Burners 1 Turn valve or thermostat...

Страница 24: ...o make this adjustment 1 Turn thermostat dial to 300 F Burner should light Observe burner through slots in grease trough 2 After temperature rises and remains constant turn dial back to low This closes main valve and permits only by pass gas to burner 3 Remove dial 4 With a screwdriver turn by pass flame adjuster screw counterclockwise to increase the bypass flame or clockwise to decrease it until...

Страница 25: ...til flame cuts down to by pass After sufficient time check temperature If the temperature does not read within 15 degrees of the dial setting recalibrate as follows 5 Hold calibration plate and loosen the two calibration lock screws until the plate can be moved independently of the control 6 Turn calibration plate so that the instrument or thermometer reading is in line with the indicator mark as ...

Страница 26: ...at until flame cuts down to bypass After sufficient time check temperature If the temperature does not read within 25 degrees of the dial setting recalibrate as follows 5 Hold calibration plate and loosen the two calibration lock screws until the plate can be moved independently of the control 6 Turn calibration plate so that the instrument or thermometer reading is in line with the indicator mark...

Страница 27: ...low three such cycles for the temperature to stabilize 7 Read the pyrometer or thermometer immediately after the light goes out for the third time and again immediately after it comes on the next time 8 If the average of these readings and the dial setting vary by more than 15 degrees recalibrate be following the instructions outlined below TO RECALIBRATE NOTE Recalibration should be attempted onl...

Страница 28: ...top burner in OFF position Pilot out Top burner not oven will not come on Clogged burner charge port open top burners Pilot gas not adjusted properly Clogged orifice Draft condition Improper ventilation system Top section pilot will not stay ignited Air in gas line STANDARD TYPE OVEN Problem Look For Manual valve for oven in OFF position Oven will not come on Oven pilot is out Pilot gas not adjust...

Страница 29: ...e oven C 6 Slide the capillary bulb out of the oven cavity into the control box area for complete removal D COOLING BLOWER To service the cooling blower follow the same steps as for removal of the oven thermostat After the oven thermostat has been removed the control box assembly complete with the cooling blower can be removed totally from the unit E 208 236V 50 VA TRANSFORMER The transformer is l...

Страница 30: ...SERVICE SECTIONAL RANGES SECTION THREE SERVICE PAGE 9 ...

Страница 31: ...SERVICE SECTIONAL RANGES SECTION THREE SERVICE PAGE10 Litho in U S A 4 92 ...

Страница 32: ...rmostat 4440300 Motor 115V 1165771 1166061 Cooling Blower Common for both 4440300 Motor 220 VAC 50 Hz 1165898 120V or 208 236V 1162843 Terminal Block 208 236V 1167003 Relay 208 236V Units 1171891 50 VA Transformer 208 236V 1160533 Oven On Off Knob 1164805 Flame Switch 1021300 Oven On Off Valve 1164807 Spark Electrode 4440300 Motor 208 236 VAC 60 Hz 1166085 1142000 Door Switch 1165733 Oven Burner B...

Страница 33: ... 1 1 1 1 1 1160532 VALVE KNOB 1 1 1 1 1 1 1 1 1038099 TOP PILOT 1 1 1 1 1 1 1 1 1884 BURNER ASM 1 1 1 1 1 1 1 1 1018998 HOT TOP PLATE 2 2 2 2 2 2 2 2 1018997 HOT TOP RING 1 1 1 1 1 1 1 1 1018996 HOT TOP LID 1 1 1 1 1 1 1 1 1109299 REAR COLLAR PLATE 1 1 1 1 1109295 REAR COLLAR PLATE 1 1 1 1 1099099 PILOT FILTER VALVE 2 1 2 1 1099002 PILOT VALVE 2 1 2 1 1362 1362 0 1 1422 1422 0 1 162 0 1 122 0 1 UN...

Страница 34: ... 1 1 1 1 1 1 1 1123498 H BURNER ASM RT 1 1 1 1 1 1 1 1 1123499 H BURNER ASM LT 1 1 1 1 1 1 1 1 1035996 GRIDDLE PLATE 1 1 1 1 1035997 GRIDDLE PLATE 1 1 1 1 1109299 REAR COLLAR PLATE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2690 GREASE BOX ASM 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1010499 GRIDDLE THERMOSTAT 2 2 2 2 2 2 2 2 1 1 1 1 1010400 THERMOSTAT KNOB 2 2 2 2 2 2 2 2 1 1 1 1 1165429 THERMOSTAT K...

Страница 35: ...2 2 2 1 1 1 1 1038099 TOP PILOT 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 B42 00005 TOP PILOT 15875 1 1 1 1 2687 FLASH TUBE 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 15878 CHARGE PORT 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1166046 BURNER INSERT 1166045 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1888 REAR OPEN TOP BURNER 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1890 FRONT OPEN TOP BURNER 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1019601 U...

Страница 36: ...4 4 4 4 4 4 4 4 2 2 2 2 4 4 4 4 2 2 1166011 VALVE KNOB 4 4 4 4 2 2 2687 FLASH TUBES 4 4 4 4 4 4 4 4 2 2 2 2 4 4 4 4 2 2 15878 CHARGE PORT 4 4 4 4 4 4 4 4 2 2 2 2 4 4 4 4 2 2 1166046 BURNER INSERT 1166045 4 4 4 4 2 2 1888 REAR OPEN TOP BURNER 2 2 2 2 2 2 2 2 1 1 1 1 2 2 2 2 1 1 1890 FRONT OPEN TOP BURNER 2 2 2 2 2 2 2 2 1 1 1 1 2 2 2 2 1 1 1166015 REAR OPEN TOP BURNER 2 2 2 2 1 1 1166014 FRONT OPEN...

Страница 37: ...1 1164424 GRATE TOP PLATE 1 1164654 REAR COLLAR PLATE 1 1164638 DIRT TRAY 1 1173385 GRATE TOP PLATE 2 2 1 1 1173457 HOT TOP PLATE 1 1 1008750 ORIFICE HOOD NAT OT 6 6 3 3 1008751 ORIFICE HOOD NAT HT 3 3 1008756 ORIFICE HOOD PROP OT 6 6 3 3 1008757 ORIFICE HOOD PROP HT 3 3 NOTE 1173385 1 Piece replaces 1 1160160 and 3 1160162 on old units which had removable spider grids Legs Casters All Units Effec...

Страница 38: ...2 1 1 1176005 Valve Body Propane 4 4 4 4 2 2 4 4 4 4 2 2 1008749 Valve Hood Propane 4 4 4 4 2 2 2 2 2 2 1 1 1179222 Valve Ext Nipple 4 4 4 4 2 2 2 2 2 2 1 1 1179240 Front Open Top Burner 2 2 2 2 1 1 2 2 2 2 1 1 1179241 Rear Open Top Burner 2 2 2 2 1 1 1179230 Burner Insert 4 4 4 4 2 2 2 2 2 2 1 1 1177043 Burner Drip Cover 4 4 4 4 2 2 2 2 2 2 1 1 1179233 Knob Open Top 4 4 4 4 2 2 2 2 2 2 1 1 117924...

Страница 39: ...C C C C C C C C C 1166004 Double Pilot Valve 1 1 1 1 1 1 1 1 1 1 1 1 1179244 Front Pilot Assembly 1 1 1 1 1 1 1 1 1 1 1 1 1179246 Rear Pilot Assembly 1 1 1 1 1 1 1 1 1 1 1 1 1176004 Valve Body Natural 2 2 2 2 2 2 2 2 2 2 2 2 1008735 Valve Hood Natural 2 2 2 2 2 2 2 2 2 2 2 2 1176005 Valve Body Propane 2 2 2 2 2 2 2 2 2 2 2 2 1008749 Valve Hood Propane 2 2 2 2 2 2 2 2 2 2 2 2 1179222 Valve Ext Nipp...

Страница 40: ...SECTIONAL RANGES SECTION FOUR PARTS PAGE 7 PARTS PARTS ...

Страница 41: ...PARTS Diagram 4 STANDARD OVEN BASE SECTIONAL RANGES SECTION FOUR PARTS PAGE 8 Litho in U S A 4 92 ...

Страница 42: ...e Roast Ovens Pizza Ovens Ranges Fryers Special Custom Equipment Convection Steamers Steam Kettles Tilting Braising Pans Cooker Mixer Kettles Floor Model Broilers Under Fired Broilers Salamander Broilers Cheese Melters Counter Top Broilers Griddles ...

Страница 43: ...professional service may be necessary to extend the useful life of this unit When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to the model number serial number and type of your unit southbend A MIDDLEBY COMPANY PART NUMBER 1161610 2 Rev 4 92 1100 Old Honeycutt Road Fuquay Varina NC 27526 919 552 9161 FAX 919 552 9798 800 348 2558 ...

Страница 44: ... 4440300 Motor Kit 115 208 240 60 1 2 2 speed 1175151 No longer available Use 4440367 or 4440368 depending on voltage NEW PARTS 4440367 Motor Replacement Kit 120 60 1 1174718 4440300 4440368 Motor Replacement Kit 208 240 60 1 3 1174719 4440300 NOTE The 4440367 is Mandatory Distributor Stock Both 4440367 4440368 are Mandatory Warranty Return This discontinued motor was universal for 115 or 208 236 ...

Страница 45: ...en Door Seal has been changed to one piece in lieu of 4 separate pieces This gives a better air seal and lowers the replacement cost DISCONTINUED PARTS 1165956 Oven Door Seal Top Bottom 1165907 1165955 Oven Door Seal Sides 1165908 2 each were required for a set These parts are no longer available NEW PART 1176296 Oven Door Seal NOTE The 1176296 is Mandatory Distributor Stock The new one piece seal...

Страница 46: ...dard Sectional Range ovens adding porcelain enamel oven interior sides top and rear to the already porcelain bottom and door lining At the same time the oven rack channels were changed from a U type steel channel to a plated round rod guide The rack was also changed to a standard plated and b a non tilt feature was added The following will clarify the where used questions DISCONTINUED PARTS 110800...

Страница 47: ... it takes the old style components a few were also made with porcelain enameled interiors that had the U channels If the oven interior is porcelain enamel and the rack guides are plated round rods it takes new style components This change does not affect any units with a CO prefix List Prices effective 1 15 94 1173545 CP 74 00 Note this is a corrected List Price 1173546 12 10 TE dy ...

Страница 48: ...om the old style to the new style for the first time an adapter is required The Kit is available for the first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1021300 Valve on off This part will be available until existing stock is depleted Then it will be obsolete and no longer available NEW PARTS 1176099 Valve on off When replacing...

Страница 49: ...List Prices effective 1 15 94 1176099 19 80 440394 27 00 1176285 3 60 Other parts are in the current price list TE dy 4440394 ...

Страница 50: ... time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1021997 Valve This part is obsolete and no longer available Some old literature lists this part as a 1021901 which was the same NEW PARTS 1176016 Valve Hi Low Natural Gas When replacing 1021997 for the first time use 4440412 Valve Replacement Kit Natural Gas This kit consists of all pa...

Страница 51: ...1160532 Knob which is still available The 1176016 Valve has S16 stamped on the flat side of the Valve Barrel List Prices effective 1 15 94 1176016 48 40 4440412 63 60 1179083 12 40 Other parts are in the current price list ...

Страница 52: ... time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1021996 Valve This part will be available until existing stock is depleted approximately 18 months Then it will be obsolete no longer available Some old literature lists this part as a 1021901 which was the same identical part NEW PARTS 1176017 Valve Hi Low Propane Gas When replacing 1...

Страница 53: ...2 Knob which is still available The 1176017 Valve has S17 stamped on the flat side of the Valve Barrel List Prices effective 1 15 94 1176017 48 40 4440411 63 60 1179083 12 40 1006433 2 80 Other parts are in the current price list ...

Страница 54: ...rst time a fitting is required The Kit is available for the first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1168276 Valve This part is obsolete and no longer available NEW PARTS 1176005 Valve Hi Low Propane Gas When replacing 1168276 for the first time use 4440403 Valve Replacement Kit Propane Gas This kit consists of all parts...

Страница 55: ...The 1176005 has the Southbend logo 05 stamped on the flat side of the valve stem List Prices effective 1 15 94 1176005 11 90 4440403 17 90 Other parts are in the current price list ...

Страница 56: ...style to the new style for the first time a fitting is required The Kit is available for the first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1168276 Valve This part is obsolete and no longer available NEW PARTS 1176004 Valve Hi Low Natural Gas When replacing 1168276 for the first time use 4440404 Valve Replacement Kit Natural G...

Страница 57: ... 1021697 Valves Both will be available in the foreseeable future The 1176004 Valve has the Southbend logo 04 stamped on the flat side of the valve stem List Prices effective 1 15 94 1176004 11 90 4440404 17 90 Other parts are in the current price list ...

Страница 58: ...from the old style to the new style for the first time fittings and a new knob are required The Kit is available for the first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1021998 Valve Propane Gas This part is obsolete and no longer available NEW PARTS 1176019 Valve Propane Gas When replacing 1021998 for the first time use 444039...

Страница 59: ... which is still available The 1176019 Valve has S19 stamped on the flat side of the Valve barrel List Prices effective 1 15 94 1176019 48 50 4440396 71 20 1176285 3 60 1179080 9 10 1006446 2 80 Other parts are in the current price list ...

Страница 60: ...een changed When changing from the old style to the new style for the first time fittings and a new knob are required The Kit is available for the first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1021999 Valve Natural Gas This part is obsolete and no longer available NEW PARTS 1176018 Valve Natural Gas When replacing 1021999 for...

Страница 61: ...Gas See Bulletin 9415 Part 1176019 4440396 The old valve used a 1160532 Knob which is still available The 1176018 Valve has 518 stamped on the flat side of the valve barrel List Prices effective 1 15 94 1176018 48 50 4440395 71 20 1176285 3 60 1179080 9 10 1006432 2 80 Other parts are in the current price list ...

Страница 62: ... to the new style for the first time fittings are required The Kit is available for the first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1076798 Valve This part is obsolete and no longer available NEW PARTS 1176003 Valve Hi Low Propane Gas When replacing 1076798 for the first time only use 4440359 Valve Replacement Kit Propane G...

Страница 63: ...s still available This valve is to be used under rear hot top plates only It is not for open burner use For other valves for these models see Bulletins 9408 9409 9410 NOTE The 1176003 Valve has S03 stamped on the flat side of the Valve barrel List Prices effective 1 15 94 1176003 11 90 4440359 37 20 1174944 7 70 Other parts are in the current price list TE dy ...

Страница 64: ...e to the new style for the first time fittings are required The Kit is available for the first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1076798 Valve This part is obsolete and no longer available NEW PARTS 1176002 Valve Hi Low Natural Gas When replacing 1076798 for the first time only use 4440358 Valve Replacement Kit Propane ...

Страница 65: ...s still available This valve is to be used under rear hot top plates only It is not for open burner use For other valves for these models see Bulletins 9408 9409 9410 NOTE The 1176002 Valve has S02 stamped on the flat side of the Valve barrel List Prices effective 1 15 94 1176003 11 90 4440358 37 20 1174944 7 70 Other parts are in the current price list TE dy ...

Страница 66: ...first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1076798 Valve This part is obsolete and no longer available NEW PARTS 1176003 Valve Hi Low Propane Gas When replacing 1076798 for the first time only use 4440344 Valve Replacement Kit Propane Gas This Kit consists of all parts also available individually 1176003 Valve Hi Low Propa...

Страница 67: ...e models see Bulletins 9408 9410 9411 The 1176003 Valve has S03 stamped on the flat side of the valve barrel List Prices effective 1 15 94 1176003 11 90 4440344 37 20 1174944 7 70 Other parts are in the current price list TE dy ...

Страница 68: ...s available for this first time change only After the original change or on new style units the valve only can be changed DISCONTINUED PART 1076798 Valve This part is obsolete and no longer available NEW PARTS 1176002 Valve Hi Low Natural Gas When replacing 1076798 for the first time only use 4440343 Valve Replacement Kit Natural Gas This Kit consists of all parts also available individually 11760...

Страница 69: ...letins 9409 9410 9411 The 4440343 Valve Kit is Recommended Stock The 1176002 Valve is Mandatory Distributor Stock The 1176002 Valve has S02 stamped on the flat side of the valve barrel List Prices effective 1 15 94 1176002 11 90 4440343 37 20 1174944 7 70 other parts are in the current Parts Price List TE dy ...

Отзывы: