43
Advanced Setup Table
Default = Factory Default Setting
Step# Description
Pg# Range
Default
36
4th Stage Deadband
27 0 - 10 Degrees
2
37
Minutes Between 1st and 2nd Stage 27 0 - 60 Minutes
2
38
Minutes Between 2nd and 3rd Stage 27 0 - 60 Minutes
2
39
Minutes Between 3rd and 4th Stage 27 0 - 60 Minutes
2
40
2nd StageTurnoff Point
27 Deadband, Setpoint
Deadband
41
3rd StageTurnoff Point
27 Deadband, Setpoint
Deadband
42
4th Stage Turnoff Point
27 Deadband, Setpoint
Deadband
43
Minutes of Fan Purge
28
0 - 3:00, 15 min. increments
0
- 0 = off
44
Wired Sensor Type
30
Remote, Supply & Outdoor
Remote
45
Control to Temp Source
31
Thermostat, Wired Remote*,
Thermostat
Wireless Remote, Average of
Wireless Remotes, Average
Thermostat and Wired Remote*,
Average All Sensors. *Option
only if prior step = “Remote”
46
Wireless Remote to Use
31
list of wifi sensors currently
first linked
linked to thermostat. *This step
sensor in
only appears if prior step =
“Wireless Remote”
list
47
Humidity Only With Heat
29 On, Off
Off
48
Fan With Humidity Demand
29 Fan On, Fan Off
Fan Off
49
Fan With Dehumidify Demand
29 Fan On, Fan Off
Fan Off
50
Cool To Dehumidify
29 On, Off
Off
51
Maximum Occ Dehum Overcool
29 0 - 5 Degrees
2
52
Maximum Unocc Dehum Overcool
29 0 - 20 Degrees
2
53
Reheat Operation W/Cool To Dehum. 29 On, Off
Off
54
Fan Off Delay
28 0 - 120 Seconds
0
55
F/C
31 Fahrenheit (F), Celsius (C) F
56
Aux Output Polarity
32 Open, Closed
Open
57
Aux Output
32 Time, Temperature,
Time
External, Economizer
58
Aux Output Program Days
32 1 Day, 5/1/1 Day, 7 Day
1
59
Day Of Week To Program
32 Sunday - Monday (S - M)
MTWTFSS
60
Aux Output Start Time
32 12am - 12am
7am
61
Aux Output Stop Time
32 12am - 12am
9pm
62
Copy
32 Yes, No
No
63
Aux Output Temp Source
33 Thermostat, Outdoor,
Remote
Remote
64
Aux Output Trigger Point Temp
33 0 - 120 Degrees
65
65
Comfort Recovery
28 On, Off
Off
cont. next page
Содержание S1-TBSU306-S
Страница 6: ...2 Get To Know Your Thermostat Setup Buttons...