![Source 1 S1-TBSU306-S Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/source-1/s1-tbsu306-s/s1-tbsu306-s_owners-manual-and-installation-instructions_1336259046.webp)
42
Advanced Setup Table
cont. next page
Default = Factory Default Setting
Step# Description
Pg# Range
Default
1
Prog Mode
24 Non, 1 Day, 5/1/1 Day, 7
Day 7
2
Available Modes
24
Heat/Cool/Auto/Off,
Heat/Cool/
Heat/Cool/Off, Heat/Off,
Auto/Off
Cool/Off
3
Backlight
17 On, Off
Off
4
Backlight Level
17
Off thru 7 levels of brightness
Level 5
5
Night Dimmer
17 On/Off
Off
6
Night Dimmer Brightness
17
Off thru 7 levels of brightness
2 (20%)
7
Night Dimmer Start Time
17 12A-12A
8:00P
8
Night Dimmer Stop Time
17 12A-12A
6:00A
9
Current Service Filter Runtime Hours 22 0-1999 Hours
0
10
Current Service Filter Calendar Days 22 0-720 Days
0
11
Current Heat Runtime Hours
23 0-1999 Hours
0
12
Current Aux Strip Heat Runtime Hours 23 0-1999 Hours
0
13
Current Cool Runtime Hours
23 0-1999 Hours
0
14
Current Override Hours
23 0-1999 Hours
0
15
Current UV Lamp Calendar Days
23 0-720 Days
0
16
Current Humidifier Calendar Days
23 0-720 Days
0
17
Set Service Filter Runtime Hours
22 0-1950 hours
0
18
Set Service Filter Calendar Days
22 0-720 Days
0
19
Set UV Lamp Calendar Days
23 0-720 Days
0
20
Set Humidifier Calendar Days
23 0-720 Days
0
21
Language
17 English, Espanol, Francais English
22
Scrolling Method
18
“L-R Slow, L-R Fast, Word
“Whole Words
L-R Slow, Word L-R Fast,
Center Fast”
Whole Word L Slow, Whole
Word R Slow, Whole Word
Ctr. Fast, Whole Word Ctr. Slow”
23
Setpoint Limits
26 0 - 3
0
24
Max Heat Setpoint
26 35 - 99 Degrees
74
25
Min Cool Setpoint
26 35 - 99 Degrees
70
26
Cycles Per Hour
26 No Limit, 2, 3, 4, 5, 6
6
27
Compressor Minimum Off Min.
26 0, 3, 5 Minutes
5
28
Min. Heat/Cool Setpoint Difference
26 0 - 6 Degrees
2
29
Number of Heat Stages
26 0 - 3
2
30
Number of Cool Stages
26 0 - 2
1
31
Number Of Compressor Stages
26 1, 2
1
32
Number of Aux Stages
26 0, 1, 2
0
33
1st Stage Deadband
27 1 - 6 Degrees
2
34
2nd Stage Deadband
27 0 - 10 Degrees
2
35
3rd Stage Deadband
27 0 - 10 Degrees
2
Содержание S1-TBSU306-S
Страница 6: ...2 Get To Know Your Thermostat Setup Buttons...