ENFSLXSS   11.14

FLASH PATTERNS

PATTERN #

SINGLE 

COLOR

DUAL COLOR

TRI-COLOR

1

QUINT

2

WARP

3

INTER-CYCLE

4

DOUBLE

5

QUAD

6

POWER PULSE

7

ROAD RUNNER

8

Q-SWITCH

9

STEADY-BURN / ROADRUNNER

(SEQUENCE TYPE 1: STEADY BURN, SEQUENCE 

TYPE 2: ROADRUNNER)

10

STEADY-BURN DRIVER TITLE 13 QUAD

(SEQUENCE TYPE 1: STEADY BURN, SEQUENCE 

TYPE 2: TITLE 13 QUAD)

11

QUAD 2

12

DOUBLE 2

13

RANDOM 1

14

RANDOM 2

OVER-VOLTAGE PROTECTION

When an over-voltage condition is detected, the module will flash an over-voltage warning pattern of 50mS ON/950mS OFF to alert of the over-voltage condition and protect the electronics from damage due to heat/voltage.

THERMAL COMPENSATION PROTECTION

The LED module is designed to provide maximum power output while providing protection to the electronic components by reducing the output power at extreme temperatures.

SYNC 2

Syncronizing the flashing of multiple light modules is accomplished by connecting the Green and/or Blue wires of different light modules together.  Up to 24 light modules can be connected for syncronized flashing.  All light module flash patterns 

must be set to the same flash pattern # to ensure proper operation.  Refer to the Sequence Type section (in Set-Up Table)  to setup light modules to flash in alternate or simultaneous flash pattern.  NOTE: Will NOT work with non-Sync 2 prod-

ucts such as Ghost, LED3, and Single Color Intersector.

Содержание nFORCE ENFSSS**-Single Series

Страница 1: ...m to 5 p m at 1 800338 7337 press 4 to skip the automated message Questions or comments that do not require immediate attention may be emailed to techservices soundoffsignal com SUPERIOR CUSTOMER RELATIONSHIPS SMARTLY DESIGNED LIGHTING ELECTRONIC SOLUTIONS HIGH CURRENT interconnects must be properly terminated Poor crimp quality can cause heat build up and fire Follow crimp connector manufacturer ...

Страница 2: ...on and protect the electronics from damage due to heat voltage THERMAL COMPENSATION PROTECTION The LED module is designed to provide maximum power output while providing protection to the electronic components by reducing the output power at extreme temperatures SYNC 2 Syncronizing the flashing of multiple light modules is accomplished by connecting the Green and or Blue wires of different light m...

Страница 3: ...GLE DUAL TRI 12V FLASH FLASH DUAL FLASH CLR 1 2 3 12V FLASH LOW PWR FLASH CLR 1 2 LOW PWR FLASH CLR 1 2 3 LOW PWR 12V 12V FLASH LOW PWR FLASH COLOR 1 2 LOW PWR FLASH CLR 1 2 3 LOW PWR 12V NO OP NO OP NO OP 12V 12V FLASH LOW PWR FLASH COLOR 1 2 LOW PWR FLASH CLR 1 2 3 LOW PWR 12V 12V FLASH LOW PWR FLASH COLOR 1 2 LOW PWR FLASH CLR 1 2 3 LOW PWR 12V 12V 12V FLASH LOW PWR FLASH COLOR 1 2 LOW PWR FLAS...

Страница 4: ... high then release The flash pattern will advance to the next pattern If the light module was at the last pattern the pattern will reset to the 1st pattern BACKUP PATTERN This function is only valid when the LED module is in a flashing mode disabled in cruise or steady ON functions When the light is flashing momentarily connect the white or yellow wire to ground for 1S and 2S light will go steady ...

Страница 5: ...OCATION 4X Ø 0 625 HOLE 2X PILOT HOLE LOCATION 2X 2 46 4 91 0 625 HOLE SINGLE SURFACE MOUNT TEMPLATE Important Printer Note From the print screen click on Actual Size in order for the template to print to it s proper dimensional size Verify dimensions are correct before using template to drill any permanent holes ...

Страница 6: ...olor Swap ON Color Swap OFF Color Swap ON Color Swap OFF Color Swap ON Cruise Cruise Color 1 Cruise Color 1 Cruise Color 2 Cruise Color 1 Cruise Color 2 Cruise Cruise Color 2 Cruise Color 1 Cruise Color 2 Cruise Color 1 Cruise Cruise Cruise Color 2 Cruise Color 1 Cruise Color 3 Cruise Color 3 Flash Flash Color 1 Flash Color 1 Flash Color 2 Flash Color 1 Flash Color 2 Flash Flash Color 2 Flash Colo...

Отзывы: