background image

DIRECTIONAL ARROW SWITCH

PAGE 2

CONNECTING THE WIRES:

Black Wire (Ground)

 

Connect to Reliable Ground

 

To minimize field service issues, it is recommended that the ground wires be  

 

connected directly to the ground terminal of the battery.

Red Wire (Power Input)

 

Connect to a re12v or +24v power source

White / Red Wire (Master / Ignition switch)

 

Connect to a re12v or +24v power source

BLACK

+12Vdc

RED

+12Vdc

WHITE/RED

Wire Color

 

Function

 

Connection

 

Black

 Ground 

Reliable Ground

 

Red

 

Constant power

 

+12v or +24v

 

White w/ Red

 

Switch

 

Master/Ignition switch

 

 

Pressing the “Left” Button will apply power to the Blue wire (Left Arrow Direction), and display the 

left arrow pattern on the yellow LED’s.

Pressing the “Center” button will apply power to the Brown Wire (Center Arrow Direction), and 

display the center out pattern on the yellow LED’s.

Pressing the “Right” button will apply power to the Green wire (Right Arrow Direction), and display 

the right arrow pattern on the yellow LED’s.

Pressing the “Warning button will apply power to the Pink or Yellow Wire, and display an alternating 

pattern on the yellow LED’s.

DIRECTIONAL ARROW SWITCH

PAGE 4

Содержание ETSWDAS02

Страница 1: ...arning mode press the warning button once The Current Warning Mode Option is designated by the yellow LEDs 1 Warning Mode setting 1 is designated by yellow LED 1 2 Warning Mode setting 2 is designated by yellow LED 2 3 Warning Mode setting 3 is designated by yellow LED 3 4 Warning Mode setting 4 is designated by yellow LED 4 5 Warning Mode setting 5 is designated by yellow LED 5 6 Warning Mode set...

Страница 2: ...s Electrical Mechanical WIRE COLORS USES DIRECTIONAL ARROW SWITCH PAGE 5 Product Configuration Mode By holding down the Left and Warning Buttons together for 2 seconds product configuration mode can be entered The unit will make a long beep and all of the buttons will turn green when product configuration mode has been entered Changing the level of brightness on the red LEDs The level of brightnes...

Страница 3: ...Reliable Ground Red Constant power 12v or 24v White w Red Switch Master Ignition switch Pressing the Left Button will apply power to the Blue wire Left Arrow Direction and display the left arrow pattern on the yellow LED s Pressing the Center button will apply power to the Brown Wire Center Arrow Direction and display the center out pattern on the yellow LED s Pressing the Right button will apply ...

Страница 4: ...reen Wire Right Arrow Direction Connect to Blue wire of the Traffic Master Please see page 10 for instructions on how to change between center output options Configure to apply power to the brown wire Center Option 1 Note If you are using optional wiring then the Dark Green and Blue wires must swap Blue Wire Left Arrow Direction Connect to the Blue wire of the Traffic Master Green Wire Right Arrow...

Отзывы: