1.800.338.7337 / www.soundoffsignal.com
4
7X3 / 6X4 P SERIES_STT
00KPJL 0822 REV B
WIRING AND TABLE INFORMATION:
OVER-VOLTAGE PROTECTION
When an over-voltage condition is detected, the module will flash an overvoltage
warning pattern of 50mS ON/950mS OFF to alert of the overvoltage condition and
protect the electronics from damage due to heat/voltage.
THERMAL COMPENSATION PROTECTION
The LED module is designed to provide maximum power output while providing
protection to the electronic components by reducing the output power at extreme
temperatures.
STOP/TAIL/TURN MODEL - WIRING DIRECTLY TO VEHICLE LIGHTING
(Does not apply to bluePRINT® Installation)
On some vehicles, the 6X4 and 7X3 mpower Stop and Turn models may not be
compatible without additional wiring due to Pulse Width Modulation (PWM) on
the vehicle's Stop, Turn, or Tail lamp circuits. The PWM cycling can cause the lights
to activate unintentionally when they are directly connected to the vehicle circuits.
Using a BCM driven relay circuit such as the trailer circuit provided in most trucks
allow for an isolated activation to the mpower lights. In cases where the vehicle
does not have trailer circuits available, aftermarket relays may be used. Please see
the schematics on
Page 5
.
WIRE HOOK-UP TABLE
WIRE COLOR:
FUNCTION:
RED
Power (Stop/Turn Function)
BLACK
Ground
GREEN**
Reserved - Factory Use
WHITE to POWER
(Flicker Stop Pattern)
ORANGE
Power (Tail Function)
** To sync multiple mPower lights, connect the Green
wire from each light together.
* Will NOT work w/ other sync products such as Ghost,
LED3, & 4 wire Intersector w/external flasher
* Will Work with Sync 2 products nFORCE Secondary
Lights, nFORCE FIT and 5 wire Intersector Lights.
BLACK
RED
WHITE
Set-up/Function
ORANGE
+Vdc
A FUSE
3
+Vdc
+Vdc
A FUSE
3
Lights are chassis-grounded. If you need to
ground-switch the light, you must isolate the lights
metal backing, heatsink, studs and/or screws from
the body of the vehicle or use a relay.
FIG. 5
STOP/TAIL LIGHT FUNCTION TABLE
WIRE
LIGHT
RED
ORANGE
WHITE
-
X
-
TAIL FUNCTION
X
-
STOP FUNCTION
X
-
X
STOP FUNCTION (FLICKER PATTERN)
FOR TURN LIGHT ONLY:
NOTE: The inputs do not support PWM input signals.
TURN LIGHT FUNCTION TABLE
WIRE
LIGHT
RED
ORANGE
WHITE
-
X
-
TAIL FUNCTION
X
-
-
TURN FUNCTION
ADVANCE PATTERN
Flash pattern can only be changed when the LED module is in a
flashing mode (disabled in cruise or steady ON functions). When
the light is flashing, momentarily connect the white wire to ground
for >250mS and <1S (light will go steady high) then release. The
flash pattern will advance to the next pattern. If the light module
was at the last pattern, the pattern will reset to the 1st pattern.
TOGGLE MODE
Momentarily, connect the white wire to ground for >2S and <3S
(light will go steady high, and steady low) then release. The output
mode will toggle between "repeat sequence" and "run sequence
once" modes.
FACTORY RESET
Momentarily, connect the white wire to ground for >1S and <2S
(light will go steady high, steady low, and off) then release. The
LED module will reset to pattern 1 and mode "run sequence once."
FLASH PATTERNS
PATTERN #
FLASHES PER MINUTE
1
1 (Steady)
2
60
3
90
4
120
PROGRAMMING MODE NOTE: The light must be powered by
the red or orange wire prior to activating the programming wire.