background image

 

3

 
 
Optionally, instead of RS 232 interface, a connector may be fitted on the rear panel to connect an 
analogue interface. In the bottom and top cover of the steel case are created slots for an air intake. 
This slots are covered by a fine net. Cooling air passes along heat sinks and goes out through a rear 
panel. Efficient cooling needs following an unobstructed area between: 
- a table and bottom cover    

- min. 15 mm 

- stacking of two units 

 

- min. 20 mm 

- a rear panel of the unit and a wall   - min. 100 mm 
 

OPERATING INSTRUCTIONS 

 
Power Supplies SPS 1000 series of class I equipment should normally be connected via a 3 line cable 
to mains PH+N+PE       50Hz, 230V

±

10%/TN-S. Protection achieved by basic insulation and 

connection to earth for all conductive parts that are capable of assuming hazardous voltage if the 
basic isolation fails. An output secondary circuit with voltages between conductors and between any 
conductor and earth, not exceeding 100V DC (basic enviroment), under normal operating conditions, 
which is separated from hazardous voltage by at least basic insulation, and which meets neither the 
requirements for an SELV circuit nor the requirements for a limited current circuit.  
Between output and input circuit (main and auxiliary transformers) is used reinforced insulation and 
creepage and clearance distance is 8mm. Based on above mentioned Power Supplies SPS 1000 series 
appear to be a safety equipment.  
Handling and operation of the SPS 1000 is very simple. 

Содержание SPS1000 SERIES

Страница 1: ...t is limited approximately to 60A 10ms This must be taken into account at a fusing of the line outlet It is recommended to use 16A normal fuse or 10A slow one The rectified 230V AC 300V DC is chopped...

Страница 2: ...nit Voltage is indicated on the 3 digit display and the current at the same time on the 3 digit display Power supply output may be turned on or off by the Disable OUTPUT switch at any time independent...

Страница 3: ...PE 50Hz 230V 10 TN S Protection achieved by basic insulation and connection to earth for all conductive parts that are capable of assuming hazardous voltage if the basic isolation fails An output sec...

Страница 4: ...ondition MAINTENANCE Power Supply SPS 1000 normally needs no maintenance or calibration Only care must be taken not to obstruct cooling of the unit When a unit is equipped by a dust filter which must...

Страница 5: ...oad inductance will not form a serial resonant circuit The output voltage is available 2s after mains switch on This feature may be improved according to customer requirements Serial operation is allo...

Страница 6: ...TTL logic and lower one could be able to trigger the thyristor crowbar under normal operating condition due to a disturb noise Avoid condensation inside the power supply break down could be the resul...

Страница 7: ...after this string send character 0x0D ENTER Meaning of each symbol S beginning of message Z power supply switched ON V power supply switched OFF Tu switch OFF power supply resp his output zero voltage...

Отзывы: