2.4
LOCATION AND MOUNTING
WARNING!
To reduce the risk of fire or electrical shock, install the SFA Series unit in a
temperature and humidity controlled indoor area, free of conductive
contaminants.
CAUTION!
The unit should be provided with proper ventilation. The rear and both sides
of the unit should be free of obstructions. To ensure proper airflow, a
minimum 4" clearance from the rear air outlet is required. The unit should
not be installed in a raised ambient temperature greater than 50°C.
CAUTION!
This unit is intended for installation in a protected environment. No user
serviceable parts inside. Service to be performed by qualified personnel
only.
The SFA Series models are designed for mounting in a standard 19-inch
equipment rack. If additional instrumentation is mounted in the rack, no
additional clearance is required between the SFA series and other power
supplies or instruments.
1.
Support the unit using rack mount slides or appropriate L brackets
(suggested parts are listed below).
Rack Mount Slide Kit:
5–15kW units Elgar P/N K550212-01
20–30kW units Elgar P/N K550213-01
2.
Secure the unit in place using the screws provided.
2.4.1
6U C
HASSIS
R
EMOVAL FROM
R
ACK
The slides have a Front Disconnect Feature and lock at full extension.
To return the chassis back into the rack from full extension, depress the flat
steel spring inward (located on the slides) and push the chassis back.
To disconnect and remove the chassis from the rack, depress the flat steel
spring inward (located on the slides) and pull the chassis forward.
WARNING!
The 6U SFA Series unit weighs up to 160 lbs (73kg) depending on the
model. A minimum three-person lift is required!
M550292-01 Rev C
2-3
Содержание SFA Series
Страница 2: ......
Страница 4: ...This page intentionally left blank M550292 01 Rev C ii...
Страница 6: ...This page intentionally left blank M550292 01 Rev C iv...
Страница 8: ...This page intentionally left blank M550292 01 Rev C vi...
Страница 10: ...This page intentionally left blank M550292 01 Rev C viii...
Страница 14: ...This page intentionally left blank iv M550292 01 Rev C...
Страница 41: ...Sorensen SFA Series Operation Figure 3 7 Remote Sensing Operation at the Load M550292 01 Rev C 3 13...
Страница 46: ...Operation Sorensen SFA Series This page intentionally left blank 3 18 M550292 01 Rev C...
Страница 52: ...Verification and Calibration Sorensen SFA Series This page intentionally left blank 4 6 M550292 01 Rev C...
Страница 56: ...Maintenance Sorensen SFA Series This page intentionally left blank 5 4 M550292 01 Rev C...