![Sony XCL-V500 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/sony/xcl-v500/xcl-v500_technical-manual_1322933040.webp)
40
Functions of the XCL-V500
XCL-X700/V500
■
External-HD Input Specifications
DC IN connector
DIGITAL IF connector
Input signals meeting the input specifications above converted to the signal level of the LVDS system (output
by the 3.3 V IC). Be aware that if the signals fail to meet the following conditions, the camera module will not
recognize the input signals properly.
H level: 1.5 V to 1.7 V
L level: 0.8 V to 1.0 V
■
External-VD Input Specifications
DC IN connector
DIGITAL IF connector
Input signals meeting the input specifications above converted to the signal level of the LVDS system (output
by the 3.3 V IC). Be aware that if the signals fail to meet the following conditions, the camera module will not
recognize the input signals properly.
H level: 1.5 V to 1.7 V
L level: 0.8 V to 1.0 V
■
HD/VD Output Specifications (only for the DC IN connector)
4.5 V
The voltage measured when terminated with 10 k
Ω
or more
0 V
75
Ω
termination ON: 5 V
75
Ω
termination OFF: 2 to 5 V
5~21H
0~0.6 V
2~5 V
The voltage measured with input impedance of 75
Ω
/ 10 k
Ω
or more
75
Ω
termination ON: 5 V
75
Ω
termination OFF: 2 to 5 V
The voltage measured with input impedance of 75
Ω
/ 10 k
Ω
or more
2.0~5.0
µ
s
0~0.6 V
2~5 V