25
Sequential
SP-TRG-MODE=2, SP-TRG-POL=0, SP-TRG-F-CNT=3 in the figure.
Trigger states
Trigger source
This can be input via the DC IN connector, Digital IF connector, or software command (TRG-SOFT). Refer to “Trigger
Signal Input” (page 15) for details. Note that the trigger sources for the special trigger operation and the trigger mode
operation are defined separately.
Trigger inhibition
Trigger input can be disabled. This function is effective when disabling the trigger signal to a specific camera in the
environment where multiple cameras are connected by the same trigger signal and when preventing false operations
caused by noise contamination to the trigger signal line (due to the installed environment).
Command
Parameter
Setting
TRG-INH
0
Trigger is accepted
1
Trigger is not accepted
Trigger signal
Exposure
Sensor output
Setting 1
Setting 2
Setting 3
5 ms or
longer
Free run
Bulk
Sequential
Trigger edge detection
Trigger width detection
Trigger mode
Trigger signal
Trigger inhibition
Exposure
Trigger
disabled
Sensor output