33
Test Chart Output
For monochrome camera, monochrome chart can be set.
For color camera, monochrome chart or color chart can
be set.
* 12 bit notation
GPIO
GPI
The value can be checked by detecting the signals input
to the DC IN connector 4th, 7th, 10th, and 11th using the
GPI command. Since all pins are pulled up, 1 (Hi level)
is returned if they are opened.
GPO
GPO1, GPO2, GPO3 and GPO4 outputs can be
transmitted from the DC IN connector 4th, 6th, 7th, and
9th pins, respectively. After selecting a signal, the output
polarity should be determined by GPO-INVERTER.
The strobe control signal can be set separately for
GPO1, GPO2, GPO3, and GPO4.
Setting example:
LVAL signal is output to GPO2 (DC IN connector 6th
pin), Hi active setting (Hi is enabled)
>GPO-SRC 6 2
>GPO-INVERTER 6 0
Command
Parameter
Setting
TESTCHART
0
Off
1
Monochrome chart
2
Color chart
Monochrome
Color
Raw/Mono
R
G
B
1
0xF30
0xFFF
0xFFF
0xFFF
2
0xDC0
0xFFF
0xFFF
0
3
0xC80
0
0xFFF
0xFFF
4
0xA00
0
0xFFF
0
5
0x7A0
0xFFF
0
0xFFF
6
0x550
0xFFF
0
0
7
0x340
0
0
0xFFF
Command
Parameter
GPI
4/7/10/11
Command Parameter1 Parameter2
Setting
GPO-SRC
4/6/7/9
0
Exposure signal
1
Strobe control signal
2
LVAL signal
3
FVAL signal
4
Sensor readout signal
5
Trigger through signal
6
Pulse generation signal
7
User definition 1
8
User definition 2
9
User definition 3
10
User definition 4
11
“L”
12
“H”
Command
Parameter
Setting
GPO-INVERTER
0
Without signal inversion
1
With signal inversion