C
o
nt
ro
l O
p
er
at
io
n
s
24
Control Operations
Camera Control Registers
There is a diagonal line in the Address column of registers for which there is a definition for XML only and there is no
address definition.
DeviceControl
1) This value is unique to the model.
ImageFormatControl
Address
Register
0x00000000
Base Address
0x00000000 - 0x00009FFC
GigE Vision Bootstrap
0xA0000000
Camera Base Address
0xA0000000 - 0xA00020BC
Camera Control
0xA00020C0 - 0xA00020FC
User Memory
0xA0003000 - 0xA00030FC
Camera Control
0xA0007000 - 0xA00070FC
Camera Control Inq
0xA0010000 - 0xA0013FFC
LUT Control
Address
Name
Type
Data
Description
0x00000068
DeviceVendorName
R/O
1)
Displays the vendor name.
0x00000088
DeviceModelName
R/O
1)
Displays the model name.
0x000000A8
DeviceVersion
R/O
1)
Displays the version.
0x000000D8
DeviceManufacturerInfo
R/O
1)
Displays the manufacturer information.
0x000000D8
DeviceID
R/O
1)
Displays the serial number.
0x000000E8
DeviceUserID
R/W
1)
Sets the user ID.
DeviceScanType
R/O
–
Displays the scan type.
0xA0000010
DeviceReset
W/O
1
Executes a device reset.
0xA0000014
DeviceTemperature
R/O
Displays the device temperature (°C).
Address
Name
Type
Data
Description
0xA0000124
SensorTaps
R/W
2,4
Sets the number of Taps to be read from the image sensor.
0xA0000100
Width
R/W
1)
Sets the number of horizontal pixels (H).
0xA0000104
Height
R/W
1)
Sets the number of vertical lines (V).
0xA0000108
OffsetX
R/W
1)
Sets the offset of the number of horizontal pixels (H).
0xA000010C
OffsetY
R/W
1)
Sets the offset of the number of vertical lines (V).
0xA0000118
BinningHorizontal
2)
R/W
1,2
Sets Horizontal Binning.
0xA0000114
BinningVertical
2)
R/W
1,2
Sets Vertical Binning.
Aegis Electronic Group
www.aegiselect.com
For More Information Please Call Aegis Electronic Group, Inc. * (888) 687-6877 Phone * [email protected] * http://www.aegis-elec.com