46
Average value detection mode
Brighter part of the object might be darker.
User Set
Main set values can be saved to the channels 1 to 16 of
USERSET. Refer to “Command List” (page 47) for
items to be saved. The factory setting is saved to channel
0, which cannot be overwritten.
Setting example (1):
Shutter is 3 ms, Gain is 3 dB, Pulse signal is output to
GPO3 connector (this setting is saved to the channel
1).
ExposureTime=3000
Gain=30
LineSelector=Line3
LineMode=Output
LineSource=PWM
UserSetSelector=1
UserSetSave
Setting example (2):
The user set saved in the channel 2 is loaded.
UserSetSelector=2
UserSetLoad
User set memory
This is one of the items to be saved in the user set
channel. Signed 32-bit numbers are assigned to slots 0 to
15.
User ID
User IDs are unique names that can be assigned to
cameras. A string that is 15 characters long can be
assigned.
Saving and Startup
The startup setting can be determined by
UserSetDefaultSelector. This is also used to check
which user set settings are currently being used.
Usage example:
Startup with the setting saved in the user set channel 3.
UserSetDefaultSelector=3
(Restart or CameraReboot command)
Check which user set settings are the current settings.
Read UserSetDefaultSelector
Camera Information
The model name of a camera or its firmware information
can be read out.
Restart
The camera is rebooted.
A time after receiving a command until rebooting can be
set in milliseconds (ms).
Register
Parameter
DeviceUserID
15 characters of your choice
Register
Parameter
DeviceVendorName
Manufacture name (SONY)
DeviceModelName
Model name
DeviceVersion
Firmware version
DeviceSerialNumber
Serial number
DeviceManufacturerInfo Data for service
Register
CameraReboot
CameraRebootDelayTime