28
Trigger edge detection (ExposureMode = Timed(0))
BurstPeriod = TriggerDuration(1)
BurstMode = DualExposureTime(2)
Trigger width detection (ExposureMode = TriggerWidth(1))
BurstFrameCount = 7
BurstMode = DualExposureTime(2)
FreeSetSequence
Multiple exposure and GPO output can be performed with a single trigger signal. The start time, length and gain of
exposure, and GPO output can be set arbitrarily. However, do not set the start time and length so that there is inversion/
overlap of the order. It is also possible to repeat the cycle with a set of exposure and GPO output set as one cycle.
* XCG-CG160/C160C: Unavailable. Dedicated to output.
Register
Parameter
Setting
FreeSetTriggerSource
Line1(0)
DC IN connector #2 pin
Line2(1)
DC IN connector #3 pin
Line3(2)
DC IN connector #4 pin*
Software(4)
Software (TriggerSoftware register)
PTP(15)
IEEE1588 sync mode
FreeSetStop
1
Forced end of FreeSetSequence
FreeSet1Cycle
1 to 10000000
Designate the length of 1 cycle of FreeSetSequence in µSec.
FreeSet1CycleNum
0 to 65533
Designate how many cycles to run FreeSetSequence. No repetition when this is 0.
FreeSetSelect
1 to 10
Designate which action parameter for which number to display/change.
FreeSetLine2Delay
-1 to 10000000
Designate the Line2 GPO exposure start time (µSec).
No output is performed in -1.
FreeSetLine2Duration
0 to 10000000
Designate the Line2 GPO output length (µSec).
FreeSetLine3Delay
-1 to 10000000
Designate the Line3 GPO exposure start time (µSec).
No output is performed in -1.
FreeSetLine3Duration
0 to 10000000
Designate the Line3 GPO output length (µSec).
FreeSetExpDelay
-1 to 10000000
Designate the exposure start time (µSec).
No output is performed in -1.
FreeSetExpDuration
0 to 10000000
Designate the exposure start time (µSec).
FreeSetGain
Same as
GainAnalogRaw
Designate the advanced gain settings of exposure (GainAnalogRaw relevance).
FreeSetSave
1
Save the settings of FreeSetSequence.
FreeSetLoad
1
Readout the settings of FreeSetSequence.
Exposure
Exposure2Time
Exposure2Time
Exposure2Time
ExposureTime
ExposureTime
ExposureTime
ExposureTime Exposure2Time
The continuous exposure will end when either one of below conditions occurred.
• Trigger signal Off is detected
• The times of exposure reaches the number specified in BurstFrameCount
Trigger signal
Exposure
Trigger signal
a X Exposure2Ratio
a
a
a
a X Exposure2Ratio
a
a X Exposure2Ratio
a