![Sony XCD-V50 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/sony/xcd-v50/xcd-v50_technical-manual_393867014.webp)
14
Control
XCD-V50CR
XCD-V50
Feature Controls
This camera supports the following features.
Shutter
Controls the exposure time. Can be controlled by both relative control values from 1/100000 of a second to 1/15s, allocated
from 1 to 3196.
Gain
Can be changed to 0 to 18 dB, subdivided in 512 steps.
Trigger
Sets external trigger mode. Trigger Mode 0 and 1 are available. Software Trigger Mode in which triggers can be output by
software.
The XCD-V50CR supports the following additional features.
White Balance
Adjusts the White Balance by adjusting the R and B gain with respect to G.
Hue
Adjusts G gain. Use this feature when you cannot obtain the correct White Balance using the R and B gain.
Before sending a command, check the predetermined variable range and check whether the feature supports
AUTO mode.
Address
Data
Bit*
F0F0050Ch
8900003Fh
0
This feature exists.
(White Balance)
4
The value can be read out.
(XCD-V50CR only)
7
Manual setting can be selected.
8-19
Min. 0
20-31
Max. 63
F0F00510h
8900003Fh
0
This feature exists.
(Hue)
4
The value can be read out.
(XCD-V50CR only)
7
Manual setting can be selected.
8-19
Min. 0
20-31
Max. 63
F0F0051Ch
89001C7Ch
0
This feature exists.
(Shutter)
4
The value can be read out.
7
Manual setting can be selected.
8-19
Min. 1
20-31
Max. 3196
F0F00520h
89000200h
0
This feature exists.
(Gain)
4
The value can be read out.
7
Manual setting can be selected.
8-19
Min. 0 (XCD-V50) or 256 (XCD-V50CR)
20-31
Max. 256 (XCD-V50) or 768 (XCD-V50CR)
F0F00530h
8C81C000h
0
This feature exists.
(Trigger)
4
The value can be read out.
5
Feature can be switched between ON and OFF.
8
Trigger Source0 exists.
15
Software Trigger Mode exists.
16
Trigger Mode0 exists.
17
Trigger Mode1 exists.
* According to the IEEE1394 specifications, the most significant bit is shown as 0.
Actual control can be carried out by setting registers from F0F00800 onward.
ddd indicates the control value expressed as a 12 bit hexadecimal number.