![Sony XCD-V50 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/sony/xcd-v50/xcd-v50_technical-manual_393867011.webp)
11
Control
XCD-V50CR
XCD-V50
For offset address 434h, the length of the
UnitDependentInfo is 11 Quadlets.
CommandRegsBase is the base address of the camera
control register.
F00 3c0000h * 4 = F0F00000h
For offset address 464h, the length of the
VendorNameLeaf is 3 Quadlets. The subsequent 8
bytes are fixed at 00. After that, the four characters for
“SONY” are entered.
For offset address 474h, the length of the
ModelNameLeaf is 4 Quadlets. The subsequent 8 bytes
are fixed at 00.
For the XCD-V50, the 7 characters “XCD-V50” come
next. For the XCD-V50CR, the 9 characters “XCD-
V50CR” come next.
Offset
0-7
8-15
16-23
24-31
Unit
434h
000B
CRC
Dependent
438h
40
3C
00
00
CommandRegsBase
Info
43Ch
81
00
00
0A
VendorNameLeaf
440h
82
00
00
0D
ModelNameLeaf
444h
38
00
00
10
Unit sub sw version
448h
39
00
00
00
Reserved
44Ch
3A
00
00
00
Reserved
450h
3B
00
00
00
Reserved
454h
3C
00
00
01
Vendor unique info 0
458h
3D
00
00
00
Vendor unique info 1
45Ch
3E
00
00
00
Vendor unique info 2
460h
3F
00
00
00
Vendor unique info 3
VendorNameLeaf
Offset
0-7
8-15
16-23
24-31
Vendor
464h
0003
CRC
Name
468h
00
00
00
00
Leaf
46ch
00
00
00
00
470h
53
4F
4E
59
“SONY”
ModelNameLeaf
Offset
0-7
8-15
16-23
24-31
Model
474h
0004
CRC
Name
478h
00
00
00
00
Leaf
47ch
00
00
00
00
480h
58
43
44
2D
“XCD-”
484h
56
35
30
00
“V50”
The offset address of VendorNameLeaf is required to
be
43Ch + 000002Ah * 4 = 464h
The offset address of ModelNameLeaf is required to
be
440h + 000005Dh * 4 = 474h
Unit sub sw version indicates that this camera
conforms to IIDC Version 1.31.