![Sony XCD-V50 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/sony/xcd-v50/xcd-v50_technical-manual_393867010.webp)
10
Control
XCD-V50CR
XCD-V50
With the exception of bits 8 to 15 of the 400h offset
address field, the length of the entire ConfigROM is
made up of 21h Quadlets. So the ConfigROM from
400h to 487h is 136 bytes.
For offset address 424h, the length of the
UnitDirectory is 3 Quadlets. UnitSpecID (00A02Dh)
conforms to 1394TA standards. UnitSoftwareVersion
(000102h) conforms to IIDC Standards, Version 1.3X.
The offset address of UnitDependentInfo is required to
be
430h + 000001h * 4 = 434h
Offset
0-7
8-15
16-23
24-31
Bus
400h
04
21
ROM CRC
Info
404h
31
33
39
34
Block
408h
20
FF
60
00
40ch
08
00
46
02
NodeVendorID/ChipID-Hi
410h
00
10
00
01
ChipID-Lo
Root
414h
0003
CRC
Directory
418h
03
08
00
46
ModuleVendorID
41ch
0C
00
83
C0
420h
D1
00
00
01
UnitDirectoryOffset
Offset
0-7
8-15
16-23
24-31
Unit
424h
0003
CRC
Directory
428h
12
00
A0
2D
UnitSpecID
42Ch
13
00
01
02
UnitSoftwareVersion
430h
D4
00
00
01
UnitDependentDirectory Offset
ConfigROM
The UnitDirectory offset address is required to be
420h +000004h * 1 = 424h