26
Mode Settings
When set to Mode 2 (Reset mode)
Setting the shutter speed using trigger pulse width
*1 This is an external input signal.
*2 Exposure time (Te)
Te = Trigger pulse width + 6
µ
sec
(The effective trigger pulse width for the external
trigger shutter operation is between 2
µ
s and 1/4 s.)
*3 Normal operation is resumed when the trigger
pulse width is 1/3 s or more. The trigger falling
edge restores external trigger shutter operation. At
this time, the 50 ms after the falling edge of the
trigger pulse is an external trigger input inhibition
area. There is no guarantee of operation for any
trigger input in this period.
External trigger shutter operation
Normal operation
*
3
Mode transition state
External input
inhibition area
(50 ms)
External trigger
shutter operation
Exposure time (Te)
*
2
Exposure time
(Te)
*
2
Trigger pulse width
*
3
525 H (Bining OFF)
263 H (Bining ON)
Trigger
*
1
Video out
WEN
1 H to 2 H
*
4
1 H to 2 H
*
4
*4 A VD signal is generated after 1 H to 2 H from the
trigger falling edge, then the image is output
synchronized with the VD generation.
Note
An image is not output correctly when the next trigger
is input before the image for the previous trigger has
been output.