background image

18

Mode Settings

To Use High-rate Scan Mode (B)

In external trigger shutter mode 1, you can increase the
rate by setting the shutter speed to the trigger pulse
width, and setting the high-rate scan mode switch on
the rear panel, the trigger interval, the external VD
phase and the external VD width.
The image is centered as shown below.

Notes

• In trigger shutter mode, video out signals are output

about 1 H later than the external VD.

• In high-rate scan mode, image output and WEN

rising edge are always synchronized, but WEN width
becomes undefined. High-rate scan mode cannot be
used in external trigger shutter mode 2.

1 H

BLKG interval Tb [line]

Effective image interval X [line]

Trigger interval T [line]

X lines 494 lines

External VD

Video out

WEN

Trigger

External VD
width TW [line]

Input of the trigger falling edge terminates the image
output.
Note that input of a trigger pulse is needed in the
effective image interval to control the ending of image
output, and this affects the image at the trigger rising
edge.

Содержание XC-HR50

Страница 1: ... 2002 Sony Corporation CCD Black and White Video Camera Module XC HR50 A B2W 100 12 1 Technical Manual ...

Страница 2: ... Trigger Pulse Specifications 9 Video Output Mode 10 Bining OFF 10 Bining ON 10 About the Electronic Shutter 11 DIP Switches on the Rear Panel 11 Normal Shutter 11 External Trigger Shutter 12 Restart Reset 13 To Set Restart Reset Mode 13 To Use High rate Scan Mode A 14 External Trigger Shutter 16 To Set the External Trigger Shutter 17 To Use High rate Scan Mode B 18 Timing Chart 20 Specifications ...

Страница 3: ...sync signal output You can output HD and VD signals from a 12 pin connector by changing the setting of a rear panel switch Electronic shutter You can choose from FL flickerless mode and a wide range of image speeds 1 125 to 1 30 000 s for the best match to shooting conditions External trigger shutter function 1 4 to 1 100 000 s You can obtain a freeze picture by inputting an external trigger This ...

Страница 4: ...Camera adaptor DC 700 700CE Tripod adaptor VCT 333I Insulated type C mount lens VCL 50Y M VCL 25Y M VCL 16Y M VCL 12YM VCL 08YM Close up ring kit LO 77ERK C mount lens VCL 08YM VCL 12YM VCL 16Y M VCL 25Y M VCL 50Y M Close up ring kit LO 77ERK XC HR50 Tripod adaptor VCT 333I Camera cables CCXC 12P02N CCXC 12P05N CCXC 12P10N CCXC 12P25N Camera adaptor DC 700 700CE Conforms to new EIAJ 12 pin assignm...

Страница 5: ...ipod screw holes at the bottom These precision screw holes are for locking the camera module Locking the camera module using these holes secures the optical axis alignment You can install the camera on a tripod To install on a tripod you will need to install the VCT 333I tripod adaptor using the reference holes on the bottom of the camera 4 Reference holes at the bottom These precision screw holes...

Страница 6: ...e fast moving objects at precise locations The factory settings for these switches are for normal operation restart reset and external trigger shutter OFF For more information see Restart Reset page 13 and External Trigger Shutter page 16 4 Gain switch bit 9 This switch selects FIX fixed or MANUAL manual adjustment factory setting FIX left side 5 Bining mode switch bit 0 Switches the video signal ...

Страница 7: ...put Signal Reset Signal VD input Signal 8 9 10 WEN output Signal 11 Trigger pulse input Signal 12 VD output Ground VD input Ground Reset Ground Reset Ground Rear panel Factory mode settings of rear panel Number Switch name Factory mode setting 1 Shutter speed and mode setting DIP switches All bits are OFF left 2 75Ω termination switch ON 3 M GAIN control knob 4 HD VD signal input output switch EXT...

Страница 8: ...ternal reset instability and high rate interval instability When you restart reset the camera or operate the camera by inputting an external trigger shutter pulse the V sync signal for the image is output about 1 H later from the external VD Mode Settings During normal operation HD phase 31 78 µs VD phase 16 68 ms 8 357 ms bining ON OFF continuous Phase timing is as shown above falling edge only a...

Страница 9: ...in multi connector on the rear panel 0 V 4 5 V HD VD 4 5 V 0 V 4 5 V 0 V HD Input Specifications Input impedance 75Ω or 10 kΩ or more Input amplitude 2 0 to 5 0 Vp p for both 75Ω termination ON and OFF The voltage and pulse width used are as measured at pin 6 of the 12 pin multi connector on the rear panel Trigger Pulse Specifications Input impedance 10 kΩ or more The voltage and pulse width used ...

Страница 10: ...ndent pixel are output from the VIDEO OUT connector every 1 60 s line sequential output External synchronization is possible by external HD VD Bining ON Mixed signals for vertically adjacent pixels are output from the VIDEO OUT connector every 1 120 s External synchronization is possible by external HD VD Frame image Frame image Frame image ODD image ODD image ODD image ODD image ODD image Rear pa...

Страница 11: ... and in external trigger shutter mode 1 Normal Shutter This mode provides continuous video output with the electronic shutter selected by switches to capture a high speed moving object clearly 8 8 Other modes refers to restart reset mode and external trigger shutter mode Rear panel DIP switches Switches 1 to 4 Shutter speed switches Switch 5 High rate scan mode switch Switches 6 to 8 Trigger shutt...

Страница 12: ...4 1 2 3 4 1 250 1 500 1 1000 1 2000 1 4000 1 10000 1 15000 1 30000 1 100 Normal shutter speed settings Unit seconds External Trigger Shutter By inputting an external trigger pulse the camera is able to capture fast moving objects clearly For more information see External Trigger Shutter page 16 ...

Страница 13: ... mode simultaneously set the high rate scan mode switch 5 to ON right side Long exposure The Restart Reset function extends the CCD accumulation time resulting in highly sensitive image capture This function is effective when you cannot gain satisfactory sensitivity under normal operating conditions or when you want to observe the trail of a moving object Extend the VD interval T between external ...

Страница 14: ...witch and the external VD width and frequency The image obtained is centered as shown below Note In Restart Reset mode video out signals are output about 1 H later than the external VD 494 lines X lines 1 H BLKG interval Tb line Effective image interval X line External VD interval Tv line External VD VBLKG Video out External VD width TW line ...

Страница 15: ...xternal VD width Tw line High rate scan OFF 9 13 17 Effective lines X line 241 7 66 ms 155 4 93 ms 107 3 40 ms 59 1 87 ms BLKG interval Tb line 20 0 636 ms 20 0 636 ms 24 0 763 ms 28 0 890 ms Frame rate frame s 120 180 240 362 Because the CCD has 494 vertical effective pixels 11 lines of invalid pixels are output at the end of the image when high rate scan is OFF VD interval 525 effective pixels 4...

Страница 16: ... for the timing in which video signals are obtained Mode 1 Non reset mode In this mode a video signal synchronized with a VD signal is output after a trigger pulse is input The video signal is synchronized with the external VD signal when an external HD VD signal is input The video signal is synchronized with an internal VD signal when no external HD VD signal is input External or internal synchro...

Страница 17: ...video signal will be output if you input a new trigger pulse before the video signal output for the previous trigger pulse is output completely To Set the External Trigger Shutter There are two ways to set the shutter speed Using the DIP switches on the rear panel For shutter speeds see the following table Mode 1 Non reset mode Mode 2 Reset mode 1 125 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 ...

Страница 18: ... later than the external VD In high rate scan mode image output and WEN rising edge are always synchronized but WEN width becomes undefined High rate scan mode cannot be used in external trigger shutter mode 2 1 H BLKG interval Tb line Effective image interval X line Trigger interval T line X lines 494 lines External VD Video out WEN Trigger External VD width TW line Input of the trigger falling e...

Страница 19: ...sed by trigger input Note that there is no difference in the number of effective lines between Bining ON and Bining OFF Because the CCD has 494 vertical effective pixels 11 lines of invalid pixels are output at the end of the image when high rate scan is OFF VD interval 525 effective pixels 494 BLKG segment 20 11 invalid pixels Effective lines X line 494 16 0 ms 237 7 53 ms 146 4 64 ms 100 3 18 ms...

Страница 20: ...rigger edge 1 and 2 in the figure it is not defined whether the image is output for the external VD falling edge or the image is output for the next external VD falling edge 1 in the figure shows that the image is output for the next external VD 2 shows the image for the external VD In this case see WEN since output of the image and WEN make up a pair In any other case the image is output for the ...

Страница 21: ...ea There is no guarantee of operation for any trigger input in this period 4 Input the external VD within the period of 10 µs to 65 ms after the trigger falling edge 1 and 2 in the figure There is no guarantee of operation for any other input If an invalid signal is input the input is changed to a valid signal and after several V signals normal operation resumes Note Make sure that the trigger sig...

Страница 22: ...nternal VD falling edge after the trigger falling edge 1 and 2 in the figure If the period from the trigger falling edge to the internal VD falling edge T in the figure is under 10 µs it is not defined whether the image is output for the internal VD falling edge or the image is output for the next internal VD falling edge 3 in the figure shows that the image is output for the next internal VD In t...

Страница 23: ...0 ms External trigger shutter operation Exposure time Te 2 Exposure time Te 2 Trigger pulse width 3 T T under 10 ms 4 525 H Bining OFF 263 H Bining ON Exposure time Te 2 2 µs to 250 ms T T 10 ms or more 4 T T 10 ms or more 4 Trigger 1 External HD 1 Video out WEN External VD 1 Continuous VD 4 An image is output when an external VD signal falls 10 ms or more after a trigger pulse rises 2 and 3 in th...

Страница 24: ...trigger input in this period 1 1 2 2 4 Input the external VD within the period of 10 ms to 75 ms after the trigger rising edge 1 and 2 in the figure There is no guarantee of operation for any other input If an invalid signal is input the input is changed to a valid signal and after several V signals normal operation resumes Note Make sure that the trigger signal and the VD signal make up a pair An...

Страница 25: ...s 2 and 3 in the figure If the period from the trigger rising edge to the internal VD falling edge T in the figure is under 10 ms it is not defined whether the image is output for the external VD falling edge or the image is output for the next external VD falling edge 1 in the figure shows that the image is output for the next internal VD In this case see WEN since the image and WEN make up a pai...

Страница 26: ... trigger pulse is an external trigger input inhibition area There is no guarantee of operation for any trigger input in this period External trigger shutter operation Normal operation 3 Mode transition state External input inhibition area 50 ms External trigger shutter operation Exposure time Te 2 Exposure time Te 2 Trigger pulse width 3 525 H Bining OFF 263 H Bining ON Trigger 1 Video out WEN 1 H...

Страница 27: ...trigger input inhibition area There is no guarantee of operation for any trigger input in this period T 4 External trigger shutter operation Normal operation 3 Mode transition state External input inhibition area 50 ms External trigger shutter operation Exposure time Te 2 Exposure time Te 2 Trigger pulse width 3 525 H Bining OFF 263 H Bining ON Trigger 1 Video out WEN T 4 2 µs to 250 ms 4 The imag...

Страница 28: ... 75Ω unbalanced Output signal frequency 59 94 Hz 119 88 Hz Normal mode Bining mode Effective lines 648 494 H V Horizontal resolution 500 TV lines Sensitivity F5 6 400 lx with FIX Gain Minimum illumination 1 lx with gain manually adjusted to maximum F1 4 Video S N ratio 58 dB Gain Fixed Manually adjustable Gamma compensation 1 fixed White clip 820 mV 70 mV Read mode Normal mode Bining mode Shutter ...

Страница 29: ...0 500 600 700 800 900 1000 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 Wavelength nm Relative sensitivity Spectral Sensitivity Characteristics Typical Values Lens characteristics included and light source characteristics excluded ...

Страница 30: ...pical value 1 horizontal scan period 780 Optical black Horizontal transfer stop period Dummy bits Optical black Effective total pixels 659 Output video period 648 Horizontal blanking period 132 Values without units indicate the clock counts 31 8 µs 3 18 µs 40 7 ns HD 5 38 µs 26 4 µs HSYNC 58 0 73 µs 2 36 µs 2 28 µs 78 18 56 7 4 31 72 16 2 ...

Страница 31: ...6 µs VD HD SG 9 H 286 µs Dummy bits Optical black Optical black Optical black Vertical blanking period 20 H 636 µs Vertical Output Waveform Timing Chart Bining OFF 2 3 4 5 6 7 8 496 493 494 1 2 5 6 525 3 4 7 8 525 1 2 3 4 5 1 9 10 11 12 13 14 15 16 17 18 19 20 1 2 21 514 515 516 517 518 519 520 521 522 523 524 525 2 3 4 5 6 7 8 1 2 5 6 3 4 7 8 525 1 2 3 4 5 1 9 10 11 12 13 14 15 16 17 18 19 20 1 2...

Страница 32: ...ons Unit mm inches 2 M3 depth 3 14 5 19 32 12 1 2 29 1 3 16 29 1 3 16 27 6 0 15 27 3 0 15 1 1 8 4 9 7 32 5 1 7 32 12 1 2 30 1 3 16 15 19 32 23 7 15 16 16 5 21 32 22 7 8 42 1 7 16 20 13 16 12 1 2 4 M2 depth 3 3 M3 depth 3 8 5 16 ...

Страница 33: ...Focal distance mm inches Operation Field angle Horizontal Vertical MOD mm inches Image pickup range during maximum proximity Horizontal Vertical mm inches Back focus Flange back Weight Iris 1 2 type CCD Maximum aperture ratio Focus VCL 08YM 8 11 32 1 1 4 Manual Manual 42 6 32 6 207 8 1 4 182 9 137 2 7 1 4 5 1 2 11 54 mm 15 32 inches 17 526 mm 23 32 inches 40 g 1 oz VCL 12YM 12 1 2 1 1 8 29 6 22 4 ...

Отзывы: