23
Camera Control Commands
OPD (Optical Detector)
OPD Frame Display Setting
OPD-AE Position Setting
OPD-AE Size Setting
OPD-AWB Position Setting
OPD-AWB Size Setting
IN/OUT
VBS/YC Output Selection
H-Phase Setting
V-Phase Setting
Command
Name
OPD-DISP
Parameter 1
OPD frame display: 0 to 2
0: OFF
1: AE
2: AWB
Default is 0
Conditions
None
Process
Displays the detection frame for AE or AWB.
Command
Name
PD-AE-POS
Parameter 1
X-coordinate of center of OPD frame [%]
Settable range is 25 to 75
Default is 50
Parameter 2
Y-coordinate of center of OPD frame [%]
Settable range is 25 to 75
Default is 50
Conditions
None
Process
Sets the position of the AE detection frame.
Command
Name
OPD-AE-SIZE
Parameter 1
OPD frame width
Settable range is 50 to 100
Default is 50
Parameter 2
Y-coordinate of center of OPD frame [%]
Settable range is 50 to 100
Default is 50
Conditions
None
Process
Sets the size of the AE detection frame.
Command
Name
OPD-AWB-POS
Parameter 1
X-coordinate of center of OPD frame [%]
Settable range is 25 to 75
Default is 50
Parameter 2
Y-coordinate of center of OPD frame [%]
Settable range is 25 to 75
Default is 50
Conditions
None
Process
Sets the position of the AWB detection frame.
Command
Name
OPD-AWB-SIZE
Parameter 1
OPD frame width
Settable range is 50 to 100
Default is 50
Parameter 2
Y-coordinate of center of OPD frame [%]
Settable range is 50 to 100
Default is 50
Conditions
None
Process
Sets the size of the AWB detection frame.
Command
Name
VOUTSEL
Parameter 1
Output signal: 0 to 1
0: VBS
1: Y/C
Default is 0
Conditions
None
Process
Selects VBS or YC output signal format.
Command
Name
HPHASE
Parameter 1
H-phase setting value:
0 to 910 (NTSC)
0 to 908 (PAL)
Default is 104
Conditions
Valid only when the camera is operated with
external synchronization.
Process
Sets the H-phase adjustment value when
using external synchronization.
Command
Name
VPHASE
Parameter 1
V-phase setting value:
0 to 262 (NTSC)
0 to 312 (PAL)
Default is 10
Conditions
Valid only when the camera is operated with
external synchronization.
Process
Sets the V-phase adjustment value when
using external synchronization.