![Sony Walkman MZ-E909 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/sony/walkman-mz-e909/walkman-mz-e909_service-manual_412215013.webp)
13
MZ-E909
5-4-3. Vl PWM Duty adjustment method
1. Set the Manual mode and set the item No. to 764.
LCD display
2. Connect a digital voltmeter to TP917 (VL) on the main board
and adjust + key (Voltage up) and – key (Voltage down) on
the remote control.
Adjustment value:2.23V
Standard value:2.22 to 2.235V
MAIN BOARD
(SIDE A)
3. Press
X
key to write the adjustment value.
5-4-5.Electrical offset adjustment method
Note:
Doing adjustment by the state that a disc does not enter.
1. Confirm the power voltage is 1.5V.
2. Set to the test mode.
3. Press the – key activates the overall adjustment mode.
LCD display
4. Press the DISPLAY key.
LCD display
5. If result of electrical offset adjustment is OK,the following dis-
play appears.
LCD display
5-5. OVERALL ADJUSTMENT MODE
5-5-1. Overall adjustment mode structure
Note: The overall adjustments should be always performed in the
sequence of CD
t
MO adjustments.
5-5-2. Overall CD and MO adjustment method
1. Set the TEST MODE and press – key to set the Overall Ad-
justment mode.
LCD display
2. Insert CD disc in the set, and press
.
key to set the Overall
CD Adjustment mode.
Automatic adjustments are made.
LCD display
XXX: Item No. for which an adjustment is being executed.
5-4-4. Vd PWM Duty adjustment method
1. Set the Manual mode and set the item No. to 765.
LCD display
2. Connect a digital voltmeter to TP903(VD) on the main board
and adjust + key (Voltage down) and – key (Voltage up) on
the remote control.
Adjustment value:1.26V
Standard value:1.255 to 1.27V
MAIN BOARD
(SIDE A)
3. Press
X
key to write the adjustment value.
765
VD_PWM XX
764
VlPWM XX
000
Assy11
030
Ofst**
030
OfstOK
TEST MODE
(Display Check Mode)
Overall Adjustment
Title Display(ASSY**)
CD overall
Adjustment
.
key
VOLUME – key
key
x
MO overall
Adjustment
> N
key
> N
key
key
x
Electrical offset
Adjustment key
DISPLAY key
key
x
key
x
Power Supply
Adjustment
PLAY MODE key
XXX
CD RUN
000
Assy11
R930
D901
D902 C903
C901
L902
TP917
(VL)
Q901
C E
TP917
(VL)
digital
voltmeter
C603
C526
R807
R827
R
R806
R515
R808
C807
C559
C558
C557
C601
C806
Q501
1
43
45
50
55
56
42
TP604
TP602
TP601
TP533
TP603
IC801
1
4
8
5
RB553
4
5
1
CN551
TP903
(VD)
R805
C805
C604
C529
digital
voltmeter
TP903(VD)
Содержание Walkman MZ-E909
Страница 32: ...32 MZ E909 ...