10
MZ-E909
4-6-2. Self-diagnostic mode
1. Set the TEST MODE.
2. With all the LCD display segments blinking on the set, press
DISPLAY key and
>B
key, the Self-diagnostic mode is
entered.
3. Hereinafter, each time
> N
key is pressed, the reference
information display changes as follows:
• Press
.
key to go back to the previous display.
• Contents of the history codes
History code number
Contents
1
The first error that occurred.
N
The last error that occurred.
N-1
The first error from the last one.
N-2
The second error from the last one.
R
Total recording time ( – – – – is displayed
for MZ-E909)
Contents of fault
Display code
Meaning of code
Simplified
Description
contents
No error
00
No error
– – – –
No error
01
Access target address illegally specified
Adrs
An attempt to access an abnormal address.
Servo system error
02
HIGH TEMP
Temp
HIGH TEMP
03
FOCUS ERROR
Fcus
Focus off-center.
04
SPINDLE ERROR
Spdl
Abnormal rotation of disc
11
TOC ERROR
TOC
TOC error
12
READ DATA ERROR
Data
Power system error
22
LOWBATT
LBat
Instantaneous interruption detected.
31
OFFSET ERROR
Ofst
Offset error
Offset error
32
FE_ABCD_OFFSET_ERR
ABCD
FE ABCD Offset error
33
TE_ABCD_OFFSET_ERR
TE
TE ABCD Offset error
34
X1_TE_OFFSET_ERR
X1TE
X1 TE ABCD Offset error
001
1 A d r s
History code
Error display code
Simplified contents
0
XX
1 #
#
#
#
0
XX
N #
#
#
#
0
XX
N1 #
#
#
#
0
XX
N2 #
#
#
#
0
XX
R
– – – –
• Description of the error display codes
4-6-3. Clearing the error display code
After servicing, reset the error display code.
1. Set the TEST MODE.
2. Press the DISPLAY key on the remote control activates the self-
diagnosis display mode.
3. To reset the error display code press
X
key on the remote con-
trol when the code is displayed.(except for R - - - - display)
(All the data on the 1st, N, N-1 and N-2 will be reset)
4. Press
X
key on the remote control again.