12
MZ-E909
C910
R910
R951
R965
R964
R909
R903
C909
C921
C908
C905
L905
C907
10
14
15
20
25
28
29
30
IC901
D903
TP901
(VC)
TP901 (VC)
digital voltmeter
5-4. MANUAL POWER ADJUSTMENTS
5-4-1. Adjustment sequence
The adjustments should be always performed in the following se-
quence:
1
Vc PWM Duty (L) adjustment (item No.:762)
r
2
Vl PWM Duty adjustment (item No.:764)
r
3
Vd PWM Duty adjustment (item No.:765)
5-4-2. Vc PWM Duty (L) adjustment method
1. Confirm that the power voltage is at 1.5 V DC.
2. Set the TEST MODE.
3. Set the overall adjustment mode and press PLAY MODE key,
item No. will change to 762.
LCD display
SECTION 5
ELECTRICAL ADJUSTMENTS
5-1. GENERAL
In this set, CD and MO discs can be automatically adjusted by set-
ting the Overall Adjustment mode within the TEST MODE,
Before performing these automatic adjustments, it is necessary to
clear the memory and adjust the power in the Manual mode.
5-2. NOTES FOR ADJUSTMENT
5-2-1. Jigs
• CD disc
TDYS-1 (part code: 4-963-646-01)
• MO disc
PTDM-1 (part code: J-2501-054-A)
or commercially available MO disc (recorded)
• Digital voltmeter
5-2-2. Adjustment sequence
The adjustments should be always performed in the following
sequence:
5-2-3. Power
The power is supplied with 1.5 V DC from the battery case.
5-3. RESET NV
5-3-1. How to reset NV
1. Set the TEST MODE.
2. Set the Manual mode and set the item No. 021, Reset NV.
LCD display
1
Reset NV (Clear the memory)
2
Manual power adjustments
3
Electrical offset adjustments
(Do not enter the disc)
4
Overall CD adjustments
5
Overall MO adjustments
6
RESUME clear
7
Rewrite the NV value
Overall adjustment mode
Manual mode
3. Press
X
key on the remote control.
LCD display
4. Press
X
key on the remote control again.
LCD display
5. Press
x
key to terminate the Manual mode and return to the
TEST MODE.
021
Res NV CC
021
Res OK?
021
Res ***
021
Reset!
After reset is completed.
4. Connect a digital voltmeter to TP901 (VC) on the main board
and adjust + key (voltage up) and – key (voltage down) on
the remote control.
Adjustment value:2.35V
Standard value:2.34 to 2.355V
MAIN BOARD
(SIDE A)
762
VclPWM XX
5. Press
X
key to write the adjustment value.
Содержание Walkman MZ-E909