2-9
VPL-PX35/PX40
2-4. Service Know-How
2-4-1. When the Prism Block Is Replaced
1.
Perform the V COM adjustment. (Refer to Section “2-
2. VCOM Adjustment”.)
2.
Write the GAMMA data of the prism block.
3.
Perform the white balance adjustment. (Refer to
Section “2-5. White Balance Adjustment”.)
2-4-2. When the C Board Is Replaced
n
If any board other than the C board is replaced, there is not
adjustment item.
1.
Install IC706 of the C board before replacement, into
the new C board.
2.
Enter the Factory Mode.
3.
Perform the V COM adjustment. (Refer to Section “2-
2. VCOM Adjustment”.)
4.
If the white balance is significantly poor, perform the
white balance adjustment. . (Refer to Section “2-5.
White Balance Adjustment”.)
2-5. White Balance Adjustment
Preparation before adjustment
1.
Input the 100 IRE flat field signal to the INPUT-D
connector and allow the warm-up of 10 minutes aging
at a minimum.
2.
Enter the Service Mode.
Press the keys in the following order.
[ENTER]
→
[ENTER]
→
↑
→
↓
→
[ENTER]
.
The message [Do you want to enter the Service Mode?
Yes :
↑
No :
↓
] appears.
Select [Yes :
↑
].
[Supplementary information: How to Exit the
Service Mode]
Perform the step 2 KEY operation.
The message [Do you want to return to the User Mode?
Yes :
↑
No :
↓
] appears.
Select [Yes :
↑
].
2-5-1. HIGH Mode of INPUT-D
Connect the10-step signal to the INPUT-D connector and
measure the chromaticities at each brightness.
If chromaticities are different at each brightness, perform
the following adjustment.
1.
Input the 100 IRE flat field signal to the INPUT-D
connector.
2.
Measure the chromaticity (x, y).
3.
Input the 80 IRE flat field signal.
4.
Adjust the GAIN R and GAIN B in the HIGH mode of
W/B until the chromaticity (x, y) that is measured at
step 2 is obtained.
5.
Input the 30 IRE flat field signal.
6.
Adjust the BIAS R and BIAS B in the HIGH mode of
W/B until the chromaticity (x, y) that is measured at
step 2 is obtained.
7.
Repeat steps 3 to 6 until the chromaticity (x
±
0.002, y
±
0.004) with reference to the chromaticity (x, y) that
is measured at step 2 is obtained.
Содержание VPL-PX41
Страница 6: ......
Страница 38: ......
Страница 40: ...4 2 VPL PX41 Top Cover 4 2 Exploded Views 2 8 5 6 11 1 9 4 10 7 10 3 ...
Страница 46: ...4 8 VPL PX41 Chassis 2 302 309 310 303 310 310 310 301 307 310 310 310 310 310 308 306 310 304 305 B 3x8 ...
Страница 52: ...4 14 VPL PX41 OPT Unit Assy 2 608 601 602 610 611 612 604 603 606 605 616 613 614 615 609 616 607 ...
Страница 134: ......
Страница 136: ...English Sony EMCS Corporation 2005BR16 1 Ichinomiya Tec 2005 2 VPL PX41 SY E 9 872 746 01 ...