VPL-PX41
SAFETY CHECK-OUT
After correcting the original service problem,
perform the following safety checks before
releasing the set to the customer :
Check the metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC
leakage. Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to
earth ground and from all exposed metal parts to
any exposed metal part having a return to
chassis, must not exceed 0.5 mA. Leakage
current can be measured by any one of three
methods.
1. A commercial leakage tester, such as the
Simpson 229 or RCA WT-540A. Follow the
manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The
Data Precision 245 digital multimeter is
suitable for this job.
3. Measuring the voltage drop across a resistor
by means of a VOM or battery-operated AC
voltmeter. The “limit” indication is 0.75 V, so
analog meters must have an accurate low-
voltage scale. The Simpson 250 and Sanwa
SH-63Trd are examples of a passive VOM
that is suitable. Nearly all battery operated
digital multimeters that have a 2 V AC range
are suitable. (See Fig. A)
To Exposed Metal
Parts on Set
Fig A. Using an AC voltmeter to check AC leakage.
AC
voltmeter
(0.75V)
Earth Ground
0.15
µ
F
1.5 k
Z
Содержание VPL-PX41
Страница 6: ......
Страница 38: ......
Страница 40: ...4 2 VPL PX41 Top Cover 4 2 Exploded Views 2 8 5 6 11 1 9 4 10 7 10 3 ...
Страница 46: ...4 8 VPL PX41 Chassis 2 302 309 310 303 310 310 310 301 307 310 310 310 310 310 308 306 310 304 305 B 3x8 ...
Страница 52: ...4 14 VPL PX41 OPT Unit Assy 2 608 601 602 610 611 612 604 603 606 605 616 613 614 615 609 616 607 ...
Страница 134: ......
Страница 136: ...English Sony EMCS Corporation 2005BR16 1 Ichinomiya Tec 2005 2 VPL PX41 SY E 9 872 746 01 ...