(2) RESPONSE Command

COMMAND 

fi

 eld for RESPONSE has three sub 

fi

 elds shown as follows.

Fig. 4-8 COMMAND Filed for RESPONSE

1) RESPONSE 

sub 

fi

 eld

 

The response returns the result of the request.

 
 

OK (01h) Indicates that the request was executed correctly.

 

NG (00h) Indicates that the request is illegal or cannot be executed.

 

(1-1) OK Response

 

For SET Request, the packet format will be as follows.

 

If the response for SET Request is OK, DATA 

fi

 eld should be 00h. Therefore, DATA LENGTH 

fi

 eld 

should be 00h as well.

 

For Get Request, the packet format will be as follows.

 

If the response for GET Request is OK, the DATA 

fi

 eld which follows the DATA LENGTH 

fi

 eld 

should be 

fi

 lled with returned data.

 

(1-2) NG Response

 

For SET/GET Request

 

If the response for SET/GET Request is no good, DATA 

fi

 eld which follows the DATA LENGTH 

fi

 eld should be 

fi

 led with “ERROR CODE”. “ERROR CODE” are de

fi

 ned in 7. of the section 4-3-2.

 
2)  ITEM NO sub 

fi

 eld

 

Refer to 6. of the section 4-3-2.

3)  DATA LENGTH sub 

fi

 eld

 This 

sub 

fi

 eld shows the length in byte of the DATA 

fi

 eld in the SDCP packet. The maximum data 

length is 128 bytes. If there is no data to be sent, its value should be 0h.

RESPONSE(1)

ITEM NO(2)

DATA LENGTH(1)

OK[01h]

ITEM NO(2)

DATA LENGTH[00h]

OK[01h]

ITEM NO(2)

DATA LENGTH(2)

NG[00h]

ITEM NO(2)

DATA LENGTH(2)

Содержание VPL-EW130

Страница 1: ...PROTOCOL MANUAL 1st Edition Revised 1 DATA PROJECTOR VPL EW130 VPL SX125 VPL SW125 ...

Страница 2: ...n dürfen nur von qualifiziertem Fachpersonal ausgeführt werden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux ...

Страница 3: ... Communication Specifications 7 3 3 Communication Procedure 8 3 3 1 Outline of Communication 8 3 4 Communication Rules 8 3 5 Approximate Return Waiting Times 8 3 6 Command Block Format 9 3 6 1 Simplified Command 9 3 7 Packet Examples 10 3 7 1 Change ASPECT to ZOOM 10 3 8 AMX Device Discovery 10 4 Ethernet 4 1 Service 11 4 1 1 Advertisement 11 4 1 2 PJ Talk 12 4 2 Communication Procedure 13 4 3 Pro...

Страница 4: ......

Страница 5: ... of Terms Table 1 1 Glossary of Terms Terms Abbreviated Description CONTROLLER _ Command initiator such as PCs PROJECTOR _ Front projector SDAP Simple Display Advertisement Protocol Protocol name for advertising the projector status over Ethernet SDCP Simple Display Control Protocol Protocol name for controlling projector over Ethernet PJLink _ Protocol name for controlling projector over Ethernet...

Страница 6: ... traditional portions for Ethernet general layer TCP IP UDP IP and HTTP are out of scope in this document SDCP specific command is described in the section 4 3 2 SDAP and SDCP PJ Talk are SONY original protocol stack which are described in the sections 4 3 1 and 4 3 3 respectively RS 232C Simplified Command Asynchronous Sub Command AMX Device Discovery SDAP SDCP Specific Command SNMP DDDP PJLink H...

Страница 7: ...egory ITEM List For Picture Table 1 Table 2 Remarks Item Number Data Item Upper byte Lower byte Data Byte PICTURE MODE 00h 02h DYNAMIC 0000h Set Get STANDARD 0001h PRESENTATION 0002h GAME 0003h LIVING 0004h CINEMA 0005h CONTRAST 00h 10h VALUE 0000h 0064h 0 100 BRIGHTNESS 00h 11h VALUE 0000h 0064h 0 100 COLOR 00h 12h VALUE 0000h 0064h 0 100 HUE 00h 13h VALUE 0000h 0064h 0 100 SHARPNESS 00h 14h VALU...

Страница 8: ...AL SEL 00h 32h AUTO 0000h COMPUTER 0001h COMPONENT 0002h VIDEOGBR 0003h LAMP MODE 00h 40h HIGH 0000h STANDARD 0001h LOW 0002h ITEM List For Infrared Remote Command Table 1 Table 2 Remarks Item Number Data Item Upper byte Lower byte Data Upper byte Lower byte Infrared Remote Command 15 bit category 17h Refer to Section 2 1 2 1 _ 00h 00h Set only Infrared Remote Command 20 bit E category 19h _ 00h 0...

Страница 9: ...y LAMP ERROR 01h FAN ERROR 02h COVER ERROR 04h TEMP ERROR 08h STATUS POWER 01h 02h STANDBY 00h STARTUP LAMP 02h POWER ON 03h COOLING1 04h COOLING2 05h SAVING COOLING1 06h SAVING COOLING2 07h SAVING STANDBY 08h LAMP TIMER 01h 13h VALUE xxh SUB ROM VERSION 01h 1Dh VALUE xxh MAIN ROM VERSION 01h 1Eh VALUE xxh STATUS SECURITY 01h 1Fh DISABLE 00h ENABLE 01h ...

Страница 10: ...S SHARPNESS _ PICTURE MUTING STATUS ON STATUS OFF MENU VIDEO INPUT A INPUT B POWER ON POWER OFF 3x CURSOR CURSOR CURSOR CURSOR 4x PITCH SHIFT 5x INPUT TOGGLE ENTER S VIDEO 6x 7x RESET 20bit PROJECTOR E x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x 1x 2x 3x V KEYSTONE 4x 5x 6x APA PHASE FREEZE DIGITAL ZOOM DIGITAL ZOOM _ ASPECT TOGGLE 7x 20bit PROJECTOR EE x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB x...

Страница 11: ...splay Presence absence of calling signal Pin numbers not indicated as D Sub 25 Pin are not used Assured cable length 15 m However assurance may not be applicable for some cables The software for controlling the projector from a PC is intended for performing transmission and recep tion for only the TxD and RxD lines Therefore the handshake normally performed by RS 232C is not necessary 3 2 Communic...

Страница 12: ...sent before receiving the return data since PROJECTOR will not be able to receive that command it does not return a response to CONTROLLER Consequently no error code is also sent For detail of the waiting times for PROJECTOR to return the return data after CONTROLLER sends the command refer to the section 3 5 When a communication error occurs PROJECTOR ignores the data received until now and set i...

Страница 13: ... 1001 0x9A 1001 1010 Answer 1010 1001 Answer 1011 1011 0xA9 0xBB START CODE B0 B1 B2 B4 B3 DATA ITEM NUMBER TYPE CHECK SUM 1 END CODE B5 B6 B7 A9h Put the item number Refer to the item list in the sections 2 1 1 and 2 1 2 SET 00h Set data GET 01h Get data SET Put the Data value described in the item list in the sections 2 1 1 and 2 1 2 GET Unused Set Dummy data 00h 00h Check Sum 9Ah START CODE B0 ...

Страница 14: ...lize the same purpose There is ASPECT key on the infrared remote control ler By using this key wide mode can be changed Issue the Infrared Remote Command for this key several times to set wide mode ZOOM Packet format will make as follows Refer to Section 2 1 2 for ASPECT TOGGLE START CODE A9h ITEM NUMBER 196Eh ASPECT TOGGLE SET GET 00h SET DATA 0000h CHECK SUM 7Fh END CODE 9Ah 3 8 AMX Device Disco...

Страница 15: ...ame of the equipment Serial number Serial number of the equipment Installation information Installation location of the equipment Community Community name of the equipment Power status Power status of the equipment m The category of projector is 0Ah The power status sets FFFFh if communication error occurs Protocol The SDAP protocol is defined in order to provide this service Item Description Prot...

Страница 16: ...to OFF by default Protocol Item Description Protocol name SDCP Simple Display Control Protocol Transport TCP Port number 53484 Factory shipments value TCP connection timeout 30 seconds Factory shipments value Setup Items Setup item Description Port No Port number Timeout TCP connection timeout time Host Address PC address that is able to connect Community Header community ...

Страница 17: ...ohibited that CONTROLLER send another command before receiving the response to the previous command Since PROJECTOR executes the command before sending the return data CONTROLLER must wait a while before receiving the response The waiting time depends on not only the commands but also network traffic CONTROLLER PROJECTOR SDCP SET GET Request Response OK NG The command is executed if it s valid The...

Страница 18: ... Refer to 3 of the section 4 3 2 The community that is set in the display equipment is entered Fig 4 4 COMMUNITY 3 Equipment Information PRODUCT NAME Name of equipment Maximum twelve characters In case less than twelve characters 00h is entered in the blank space SERIAL NO Serial number is entered POWER STATUS Power supply status of the equipment is entered LOCATION Information of installation loc...

Страница 19: ...2 2 CATEGORY sub field Category number 0Ah of the projector is entered here Projector checks the category number If a different category number is entered the request is ignored 3 COMMUNITY Field When the community data matches the community that is set in the display equipment the request is executed COMMUNITY field should be consist of four alphanumeric characters case sensitive All display equi...

Страница 20: ... One is the GET request to acquire the projector information and status The other is the SET request to modify the projector setup SET 00h Used to control turning the power on off and to control the input selector and to change the various setups GET 01h Used to acquire the installation information equipment status and various setup values 2 ITEM NO sub field Refer to 6 of the section 4 3 2 3 DATA...

Страница 21: ...format will be as follows If the response for GET Request is OK the DATA field which follows the DATA LENGTH field should be filled with returned data 1 2 NG Response For SET GET Request If the response for SET GET Request is no good DATA field which follows the DATA LENGTH field should be filed with ERROR CODE ERROR CODE are defined in 7 of the section 4 3 2 2 ITEM NO sub field Refer to 6 of the ...

Страница 22: ...e of Table2 Data for DATA Field O _ 1900h _ 19FFh Item Numbers are defined in the section 2 1 1 Use the value of Table2 Data for DATA Field O _ 1B00h _ 1BFFh Item Numbers are defined in the section 2 1 1 Use the value of Table2 Data for DATA Field O _ 7000h _ 7001h This is the RS 232C encapsulation mode Simple Command can be encap sulated in the DATA field For the packet format of the command refe...

Страница 23: ...haracters is less than 24 the remaining digits are filled with 00h 2 Acquire Network Setup Information This is for acquiring network setting of PROJECTOR While the upper byte is fixed as 90h the lower byte is defined as follows Lower bytes Contents SET GET 00h MAC Address _ O 01h IP Address _ O 02h Subnet Mask _ O 03h Default Gateway _ O 04h DHCP _ O 0x9000 Mac Address 6 bytes 0x9001 IPAddress 4 b...

Страница 24: ...Data 04h Short Data 11h Not Applicable Item 80h Community Error 02 h Different Community 01h Request Error 10 h Invalid Version 01h Invalid Category 02h Invalid Request 03h Short Header 11h Short Community 12h Short Command 13h Network Error 20 h Timeout 01h Comm Error F0 h Timeout 01h Check Sum Error 10h Framing Error 20h Parity Error 30h Over Run Error 40h Other Comm Error 50h Unknown Response F...

Страница 25: ... of the specified Item No is too long Example An attempt is made to set 25 bytes data in the installation location 8003h Invalid Data Data of the specified Item No is outside the setting range Example An attempt is made to set 101 in the Item when the setting range of the Item is 1 to 100 Short Data The length of data is shorter than the value specified by the data length Example The actual data l...

Страница 26: ...tegory does not match Example 0Bh is specified in the device of category 0Ah Invalid Request An unsupported request is specified Example Request 02h is specified Short Header The received data is one byte Short Community The received data is in the range of two to five bytes Short Command The received data is in the range of six to nine bytes 4 Network Error There is something wrong with TCP IP Ti...

Страница 27: ...s received 6 NVRAM Error Read Error Reading from NVRAM was failed Write Error Writing to NVRAM was failed 8 Packet Examples For setting the picture mode to dynamic the packet should be as follows HEADER VERSION CATEGORY 02h 0Ah COMMUNITY SONY 534F4E59h COMMAND REQUEST ITEM NO DATA LENGTH 00h 0002h 02h DATA 0000h The same result can be obtained by using ENCAPSULATION mode as well HEADER VERSION CAT...

Страница 28: ... POWR The following values are returned 0 Standby 1 Lamp ON 2 Cooling state 3 Warm up state 4 Unacceptable period 5 Projector defect INPT 1 Changes the projector input to RGB 2 Changes the projector input to VIDEO 3 Changes the projector input to DIGITAL 4 Changes the projector input to STORAGE 5 Changes the projector input to NETWORK INPT The following values are returned 1 RGB 2 VIDEO 3 DIGITAL ...

Страница 29: ...an be switched For source Nos refer to the section on INPT NAME Returned value is a projector name Max 64 characters INF1 Returned value is a manufacturer name Max 32 characters INF2 Returned value is a model name Max 32 characters INFO Returned value is desired information Max 32 characters CLSS Returned value is the class of the corresponding PJLINK Specifications The specifications of PJLink in...

Страница 30: ...g connection with authentication setting enabled Returns PJLINK 1 random number The random number converts a four byte integer into a character string When authentication is successful Waits for a command When authentication failed Returns PJLINK ERRA When starting connection with authentication setting disabled Returns PJLINK 0 and then waits for a command 3 PJLink Protocol Command This section p...

Страница 31: ...meter examples are as follows The input channel varies depending on the model Parameter 21 Projector input Video Parameter 22 Projector input S Video Parameter 31 Projector input Input A Parameter 32 Projector input Input B Parameter 33 Projector input Input C Parameter 34 Projector input Input D Parameter 35 Projector input Input E Parameter 36 Projector input Input F Parameter 41 Projector input...

Страница 32: ...tor s AV muting setting The available parameter examples are as follows Parameter 11 Projector video muting ON Parameter 10 Projector video muting OFF Parameter 21 Projector audio muting ON Parameter 20 Projector audio muting OFF Parameter 31 Projector video audio muting ON Parameter 30 Projector video audio muting OFF The projector responds as follows When processed properly Returns OK When param...

Страница 33: ...ill be as follows 201000 8 Lamp count lamp time inquiry LAMP This command obtains the number of the projector s lamps and the lamp time The projector responds as follows When normal Returns the lamp accumulative time and the lamp illuminated state for only the available number of lamps For the lamp illuminated state 1 represents lit while 0 represents unlit The following table shows an example of ...

Страница 34: ...nput channels varies depending on the model 21 22 31 32 33 Unacceptable period when the power status is other than Power ON Returns ERR3 Projector error occurring including warning Returns ERR4 10 Projector name inquiry NAME This command obtains the projector name The projector responds as follows When normal Returns a projector name The projector name is displayed as a nickname for the projector ...

Страница 35: ...tor responds as follows When normal Returns a space Projector error occurring including warning Returns ERR4 14 Class information inquiry CLSS This command obtains the class information The projector responds as follows When normal Returns 1 Projector error occurring including warning Returns ERR4 ...

Страница 36: ......

Страница 37: ... formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich die Vervielfältigung jeglicher Teile dieser An...

Страница 38: ...Sony Corporation VPL EW130 CN VPL EW130 SY VPL SX125 CN VPL SX125 SY VPL SW125 CN VPL SW125 SY E 9 968 822 02 Printed in Japan 2011 6 32 2011 ...

Отзывы: