– 30 –
KV-XF25N90
RM-914
2. WHITE BALANCE ADJUSTMENT
1) Set to Service Mode (Refer Section 4-1: ADJUSTMENTS
WITH COMMANDER).
2) Input white raster signal.
3) Set the PICTURE to minimum.
4) Select GCT (WHB 4) and BCT (WHB 5) with
[1]
and
[4]
, and
adjust the level with
[3]
and
[6]
for the best white balance.
5) Set the PICTURE to maximum.
6) Select GDR (WHB 1) and BDR (WHB 2) with
[1]
and
[4]
, and
adjust the level with
[3]
and
[6]
for the best white balance.
7) Write into the memory by pressing
[MUTING]
then
[0]
.
3. SUB BRIGHT ADJUSTMENT
1) Set to service mode.
2) Input a staircase signal of black to white from the pattern
generator.
3) BRIGHTNESS .... 50%.
PICTURE ............ MINIMUM
4) Select SBR (WHB7) with
[1]
and
[4]
, and adjust SBR (WHB7)
level with
[3]
and
[6]
so that the second stripe from the right is
dimly lit.
3-4. G2 (SCREEN) AND WHITE BALANCE
ADJUSTMENTS
1. G2 (SCREEN) ADJUSTMENT
1) Set the PICTURE to normal.
2) Put to VIDEO input mode without signals.
3) Connect R, G and B of the C board cathode to the oscilloscope.
4) Adjust BRIGHTNESS to obtain the cathode voltage to the value
below.
5) Adjust G2 (screen) on the FBT until picture shows the point
before cut off.
White
second from the right
Black
0 V
Cathode setting voltage:
175 V ±2(VDC)...34",25",21"
180V ±2(VDC)...29"
Содержание TRINITRON KV-XF25N90
Страница 39: ... 39 KV XF25N90 RM 914 MEMO ...