31
–
KV
-EX29M67/EX29M97/EX34M67/EX34M97
RM-963
2-12. PICTURE TUBE REMOVAL
Note:
i)
When removing the Nut, Locking; first make sure to hold the screw, special CRT
with a spanner (diameter 6) while opening the Nut, Locking using a spanner. Then
proceed to remove the Nut, special CRT using a torque driver.
ii) Remove all the necessary CRT supports located on top left and right, bottom left
and right prior to removing the CRT.
•
REMOVAL OF ANODE-CAP
NOTE : After removing the anode, short circuit the anode of the picture tube and
the anode cap to the metal chassis, CRT shield or carbon paint on the
CRT.
•
REMOVING PROCEDURES
1
Do not damage the surface of anode-caps with sharp shaped objects.
2
Do not press the rubber too hard so as not to damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built into the rubber.
3
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the rubber.
•
HOW TO HANDLE AN ANODE-CAP
3
When one side of the rubber cap is separated from the anode button, the anode-cap
can be removed by turning up the rubber cap and pulling it up in the direction of the
arrow
c
.
2
Using a thumb pull up the rubber cap firmly in the direction indicated by the arrow
b
.
1
Turn up one side of the rubber cap in the direction indicated by the arrow
a
.
a
a
b
b
c
Anode button
!
Four DGC clips
$
DGC
band
"
Degaussing coil
#
Four claws
1
Two screws
(washer head)
(+P 4
×
16)
4
Speaker
(5cm)
Nut, locking
Nut, locking
,
!ª
!ª
Two nuts,
special, CRT
2
Speaker
(15
×
6.5cm)
8
Speaker
(5cm)
Screw, crt
(Tapping 7+M8)
(KV-EX29 models only)
Screw, crt
(Tapping 7+M8)
(KV-EX29 models only)
FIGURE 1
6
Speaker
(15
×
6.5cm)
~
Tension
spring
9
Chassis assy
)
Deflection
yoke
(
Neck assy
&
C board
%
Anode cap
.
Cushion
,
Two nuts,
special, CRT
3
Two screws
(+BVTP 4
×
16)
5
7
Two screws
(washer head)
(+P 4
×
16)
Two screws
(+BVTP 4
×
16)
CRT (Top,right)
Support Assy
Two screws
(+BVTP 4
×
16)
Two screws
(+BVTP 4
×
16)
CRT (Top,left)
Support Assy
Picture tube