– 4 –
KV-DA322M64/M66
RM-GA001
[+B overcurrent OCP ]
Occurs when an overcurrent on the +B(135) line is detected by Q6804.
[High voltage protector of Horizontal Deflection]
If Q6804 go to ON, the voltage to the pin57 of IC4301 go to "HIGH".
The unit will automatically turn off.
Occurs when an overvoltage of horizontal pulse is detected by D6809.
If the voltage of anode D6809, Q6814 and D6808 goes to High, the voltage
to pin57 of IC4301 go to "HIGH".
The unit will automatically turn off.
[+B overvoltage OVP ]
Occurs when an overvoltage on the +B(135) line is detected by D6635 and
Q6606. If Q6606 go to ON, the voltage to pin2 of IC001 go to "HIGH". The
unit will automatically turn off.
[Vertical deflection failure]
Occurs when an absence of the vertical deflection pulse is detected by
Q6808. Shut down the power supply.
[White balance failure]
If the RGB levels do not balance or become low level within 5 seconds. This
error will be detected by IC4301.
TV will stay on, but there will be no picture.
[5V/9V failure]
Occurs when 5V/9V is not supplied to Micon (IC001).
No raster will be detected or no picture.
IC4301
RGB JUNGLE
CXA2170AQ
OVP
FROM
CRT (IK)
[V]
Q6808
IC001
SYSTEM
SDA
SDA
9V
5V
IC004
MEMORY
IK_IN
H PROT
RED LED
5
24
57
7
2
V PROT
56
[OCP]
Q6804, D6821
[H]
D6808, D6809
84
14,47,
82
4. SELF DIAGNOSTIC SCREEN DISPLAY
5. HANDLING SELF DIAGNOSTIC SCREEN DISPLAY
6. SELF-DIAGNOSTIC CIRCUIT
2 :
000
3 :
N/A
4 :
000
5 :
001
8 :
002
101 :
N/A
"0" means no fault has been detected.
"1" means a fault has been detected.
"2" means two faults has been detected.
"N/A" means not available for this models.
SELF DIAGNOSTIC
5
8
No.
Description
Method
1.
Display self diagnostic screen
[Display]
t
[Channel ]
t
[Volume ]
t
[Power / TV]
Note: The above must be performed while TV is on standby mode.
2.
Stop standby flash
i) Turn off power switch on main.
ii) Unplug power cord from the outlet.
3.
Clear fault result
In self diagnostic screen, press
[Channel ]
t
-
Note: Diagnostic results display on screen is not automatically cleared. Therefore,
clear result after completion of repair.
4.
Quit self diagnostic screen
Turn off power switch of remote commander or main unit.