Owner’s Record

The model and serial numbers are located on the rear panel
of the SXA-J750, on the front panel of the SXA-J751 and at
the side panel of the SX-H750. Record the serial numbers in
the spaces provided below. Refer to them whenever you call
upon your Sony dealer regarding the product.

Model No. SXA-J750

Serial No.______________

Model No. SXA-J751

Serial No.______________

Model No. SX-H750

Serial No.______________

WARNING

To prevent  fire or shock hazard, do not
expose the unit to rain or moisture.

This symbol is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.

This symbol is intended to alert the user to
the presence of uninsulated  "dangerous
voltage" within the product's enclosure that
may be of sufficient magnitude to
constitute a risk of electric shock to
persons.

For the customers in the U.S.A.

NOTICE FOR THE CUSTOMERS IN THE
UNITED KINGDOM

WARNING
THIS APPARATUS MUST BE EARTHED

IMPORTANT
The wires in this mains lead  are coloured in accordance with
the following code:

Green-and-yellow:

Earth

Blue:

Neutral

Brown:

Live

As the colours of the wires in the mains lead of this
apparatus may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire which is coloured green-and-yellow must be
connected to the terminal in the plug which is marked by the
letter E or by the safety earth symbol 

Y

 or coloured green or

green-and-yellow.
The wire which is coloured blue must be connected to the
terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the
terminal which is marked with the letter L or coloured red.

VORSICHT

Um Feuergefahr und die Gefahr eines elektrischen Schlages
zu vermeiden, darf das Gerät weder Regen noch
Feuchtigkeit ausgesetzt werden.

Für Kunden in Deutschland
Dieses Produkt kann im kommerziellen und in begrenztem
Maße auch im industriellen Bereich eingesetzt werden. Dies
ist eine Einrichtung, welche die Funk-Entstörung nach
Klasse B besitzt.

Содержание SX-H750

Страница 1: ...LINE IN D sub 15 pin 1 AC IN 3 pin 1 Output LINE OUT D sub 15 pin 1 Terminal 6 pin and 4 pin 1 Power requirements USA model 120 V AC 60 Hz European model 230 V AC 50 60Hz Power consumption USA model 0 32 A European model 30 W Dimensions 202 68 1 258 9 mm w h d 8 2 3 4 101 4 inches Mass 2 4 kg 5 lb 5 oz Supplied accessories AC power cord 1 Operating Instructions 1 SXA J751 Joint Box Input 2 54 mm p...

Страница 2: ...n Operating Instructions Before operating the unit please read this manual thoroughly and retain it for future reference 3 861 157 12 1 Wired Monitor System SXA J750 Interface Unit SXA J751 Joint Box SX H750 Wired Monitor Unit ...

Страница 3: ...HE UNITED KINGDOM WARNING THIS APPARATUS MUST BE EARTHED IMPORTANT The wires in this mains lead are coloured in accordance with the following code Green and yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured green and y...

Страница 4: ...on 5 Location and Function of Parts and Controls 6 SXA J750 Interface Unit 6 SX H750 Wired Monitor Unit 6 Precautions 7 Setting Up the System 8 System Connection 8 Pin Assignments 9 Monitoring the Conference 11 Troubleshooting Guide 11 Specifications Back cover ...

Страница 5: ...Monitor Unit This unit allows observers to listen to the conference via an earphone by selecting either the original speech or one of up to six interpreted languages Since the monitor unit is compact and light they can be placed anywhere The Sony conference system has three types of monitor systems wired infrared and inductive loop which are designed mainly for the observers at conferences using a...

Страница 6: ...ONITOR 1 2 3 4 5 6 1 2 3 4 5 6 MONITOR ORIGINAL RELAY VOLUME MIN MAX 1 2 3 4 5 6 7 8 9 COUGH CUT MICROPHONE ON ON OFF COUGH CUT SLOW VOLUME MIN MAX 1 2 3 4 5 6 7 8 9 ORIGINAL RELAY 0 10 1 2 3 4 5 6 7 8 9 MIC LINE 1 MIC LINE 2 MIC LIMIT ON OFF DIRECT ACCESS ON OFF SEAT ASIGN START END D C UNIT SP 0 10 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 0 10 1 2 3 4 5 6 7 8 9 D C UNIT MIC ORIGINAL POWER AC IN ...

Страница 7: ...s are connected successively by using the cabe with connectors at both sides Up to 60 SX H750 can be connected to one SXA J751 Decide the number of the SXA J751 according to the layout of the wired monitor units Up to two SX H750 can be connected to one SXA J751 SX H750 Wired Monitor Unit 1 CH selector 2 VOL control 3 connector 1 CH channel selector Select the channel corresponding to the desired ...

Страница 8: ...foreign objects out of the cabinet Dropping flammable or metal objects into the cabinet or spilling liquids onto the cabinet can lead to accidents In case of malfunctions If you notice any unusual sound smell or smoke turn off the power immediately disconnect the power supply and contact your Sony dealer Cleaning Clean the cabinet and panels by wiping with a soft dry cloth For severe stains moiste...

Страница 9: ...NIT INTERPRETER S UNIT 1 2 LINE MIC LINE MIC LINE 1 2 1 2 3 4 5 ORG OUT IN EXT IN 2 INTERPRETER S UNIT SX P700 MICROPHONE CHANNEL MICROPHONE CHANNEL MONITOR 1 2 3 4 5 6 1 2 3 4 5 6 MONITOR ORIGINAL RELAY VOLUME MIN MAX 1 2 3 4 5 6 7 8 9 COUGH CUT MICROPHONE ON ON OFF COUGH CUT SLOW VOLUME MIN MAX 1 2 3 4 5 6 7 8 9 ORIGINAL RELAY INTERPRETER S UNIT SX P700 MICROPHONE CHANNEL MICROPHONE CHANNEL MONI...

Страница 10: ...19 20 Signal ORG CH2 CH1 CH3 P GND CH4 CH5 CH6 NC MIC D GND 12V P GND 24 V 24 V spare for 24 V DTO OUT DTO OUT DTO OUT DTO OUT D sub 15 pin connector Pin No 2 4 3 9 5 10 12 11 1 6 13 5 13 13 7 8 14 15 Type and color of the core cable Shielded cable Brown Shielded cable Red Shielded cable Orange Shielded cable Yellow Shield of the brown shielded cable Shielded cable Blue Shielded cable Purple Shiel...

Страница 11: ...he following core cables of the 7 613 001 61 shielded cable with 16 core cables are not used Cut those cables at the shield Shielded cable White Twisted cables Yellow gray white and black The LINE IN connector D sub 15 pin of the SXA J750 is male and the LINE OUT connector D sub 15 pin is female Pin No TM1 1 TM1 2 TM1 3 TM1 4 TM1 5 TM1 6 TM2 1 TM2 2 TM2 3 TM2 4 Square 14 pin 1 2 3 4 5 6 7 8 9 10 1...

Страница 12: ...ow For more information on the troubleshooting guide refer to the manual supplied with the SX M700 M150 M100 Symptoms The POWER indicator of the SXA J750 lights even though the power of the control panel of the conference system is not turned on The POWER indicator of the SXA J750 does not light even though the power of the control panel of the conference system is turned on Possible cause remedie...