background image

Easy Maintenance of Luminance 
Level

During long periods of usage, users commonly have to 
adjust the luminance level of their projector, as Xenon 
lamps typically get darker over time.  The SRX-R320 has a 
convenient function to help users know when to make such 
adjustments.  It allows users to set a standard luminance 
level, and displays an alert message on the LCD screen of 
the projector when the value changes from the standard 
level.  With this feature, proper and timely maintenance of 
the luminance level can be performed.

Automatic Lamp Power Calibration 
Function

When switching the aspect ratio of projection from 
CinemaScope to VistaVision and vice versa, the luminance 
levels happen to change.  To maintain a constant 
luminance level even after making these changes, the  
SRX-R320 can automatically calibrate the luminance level 
by controlling the lamp output power.

Air-flow Sensor for Reliable Cooling

The SRX-R320 has a chimney on top of the unit that expels 
warm air, thereby keeping the projector unit cool.  The 
chimney has an air-flow sensor that measures the amount 
of discharged air.  When the projector is powered on from 
Standby mode, the air-flow sensor operates automatically.  
If the value does not reach a normal level, an alert 
message is displayed on the projector’s LCD screen.  
Thanks to this function, the operator can immediately 
take proactive maintenance action, allowing for reliable 
projector cooling.

Power Supply and Control of 
External Ventilation Fan

To efficiently discharge warm air from the unit, the chimney 
of the SRX-R320 projector must be connected to an exhaust 
duct with a ventilation fan.  For optimum reliability and 
effectiveness, the projector supports an Interlock interface, 
which enables the SRX-R320 to operate this external 
ventilation fan.  The projector can supply power to the fan 
and control its operation – the fan works when the projector 
is in Lamp ON mode or Standby ON mode.

Anti-tamper System

The SRX-R320 is designed to be highly secure.  It does 
not have screw holes, and requires physical keys to open 
the enclosure.  This body structure meets the anti-tamper 
requirement of the DCI.  Even if the enclosure is opened 
with the physical keys, anti-tamper sensors will trigger the 
LMT-300 Media Block to immediately start recording logs for 
further safety.  In this case, the projector also deletes Key 
Delivery Messages (KDM) automatically, so that DCP files 
cannot be played back.

SRX Controller Software

The SRX Controller software* is a convenient tool for system 
integrators to set up and maintain the SRX-R320.  This runs 
on a PC** connected to the projector via the RS-232C 
interface, and features intuitive GUIs that enable easy 
setup and adjustment of the projector.  A comprehensive 
range of setup parameters including input configurations, 
colorimetry controls, installation adjustments, and 
maintenance settings can be controlled via this software.
For example, it allows operators to easily verify a lamp’s 
operating time.  Plus, the versatile projector functions 
such as Squeeze Mode, Color Space Conversion (CSC), 
and Zoom/Focus Memory can also be controlled via this 
software. 

  * For detailed information on availability of the SRX Controller software, please 

contact your nearest Sony office.

** System requirements for the SRX Controller software: Microsoft

®

 Windows

®

 

XP Professional and Windows 7.  Supported OS languages are English and 
Japanese only.

8

Maintenance and Security Features

Содержание SRX-R320

Страница 1: ...SRX R320 4K Digital Cinema Projector LMT 300 Media Block STM 100 Theater Management System ...

Страница 2: ...2 The Standard of 4K Digital Cinema Sony s Integrated Projection System ...

Страница 3: ...age capacity of approximately 1 7 TB and adopts a reliable RAID Redundant Array of Inexpensive Disks system It can play back DCI DCP Digital Cinema Package files and allows the SRX R320 projector to show digital cinema programs Another unique feature of the LMT 300 is its Screen Management System function which is equipped as standard and can provide a variety of screen management operations such ...

Страница 4: ... theater audience In recent years stadium type seating is becoming increasingly popular among modern cinema complexes By sitting closer to the screen the audience can enjoy a more immersive visual experience However those sitting in the front rows may witness pixel artifacts when the resolution provided by the projection system is not sufficient to fill the screen size The SRX R320 provides true 4...

Страница 5: ...nsfer Function With these features the optical systems of the SRX R320 have the capacity to reproduce resolutions higher than 4K which is necessary to project 4K content exactly at 4K resolution In addition these lenses are designed to minimize chromatic aberrations using Sony s accumulated technical knowledge Variety of Interfaces The SRX R320 supports a wide variety of signal formats including t...

Страница 6: ... pixels of the SXRD device The LKRL A001 attached in front of the projector s lens extends the images in a transverse direction so that the aspect ratio of the images projected on a screen can be restored to its original 2 39 1 This can increase the brightness level of the images on the screen by approximately 20 allowing for the projector to provide a high brightness on large screens The LKRL A00...

Страница 7: ...ition of the projected images can be moved vertically and horizontally Keystone Masking To compensate for keystone distortion which typically occurs when the projector is not installed directly in front of the screen the SRX R320 has an image masking function To determine the best position for the masking this function allows users to set further two points in addition to the four corner points wh...

Страница 8: ...ntilation fan For optimum reliability and effectiveness the projector supports an Interlock interface which enables the SRX R320 to operate this external ventilation fan The projector can supply power to the fan and control its operation the fan works when the projector is in Lamp ON mode or Standby ON mode Anti tamper System The SRX R320 is designed to be highly secure It does not have screw hole...

Страница 9: ...ion technology in the silicon backplane structure and an advanced silicon wafer based assembly process The SXRD device also adopts a structure that does not use spacers These are columns found in conventional reflective liquid crystal devices to maintain a constant gap between the liquid cell floor and the top of the device Spacers tend to both scatter and reflect light which can impair high contr...

Страница 10: ...dio DCP files into AES EBU digital audio signals and then outputs them from two audio output connectors D sub 25 pin to external audio processors such as Dolby sound processors The audio output 1 and audio output 2 can support up to 8 and 16 channels respectively The timing of the audio output can be adjusted for complete synchronization with the picture and any channel can be routed to any output...

Страница 11: ...ation and key management Show Play List SPL creation and management Show schedule viewing Playback control Execution of SPLs Device configuration Device monitoring Status monitoring collect status information from the projector and Media Block report status at pre configured intervals Monitoring of cavity security status from Media Block Automation system interface Projector Power On Standby contr...

Страница 12: ...ssigned SPL lack of DCP KDM etc for schedule making Theater Management System STM 100 Creation of SPL Functions SPL creation and management Composition Play List CPL grouping functions to combine multiple compositions content programs such as trailers Customized SPL template with Cue output trigger Blank time insertion into SPL Automatically adjustable cue setting Manual transfer of SPL to auditor...

Страница 13: ... 8 442 17 1 2 640 25 1 4 740 29 1 4 344 13 5 8 726 28 5 8 88 3 1 2 1250 49 1 4 174 6 7 8 31 1 1 4 Area necessary for cooling of LMT 300 241 9 1 2 222 8 3 4 590 23 1 4 545 21 1 2 699 27 5 8 19 3 4 9 3 8 8 11 32 ø198 7 7 8 Barycentric position of SRX R320 with LKRL Z214 Barycentric position of SRX R320 with LKRL Z214 and LMT 300 for LKRL Z214 Dimensions Unit mm inches SRX R320 LMT 300 ...

Страница 14: ...f Media Block SRLV connection Remote interface D sub 15 pin female x1 RS 232C RJ 45 x1 10BASE T 100BASE TX Ethernet DCP ingest port x1 Interlock D sub 15 pin female x1 RS 232C For supply of power to an external ventilation fan and control of its operation General Power consumption Max 5 4 kW 4 2 kW lamp Max 4 2 kW 3 0 kW lamp Max 3 0 kW 2 0 kW lamp Power requirements AC 200 V to 240 V 50 60 Hz sin...

Страница 15: ... UL60950 1 CSA C22 2 No 60950 1 FCC IC EMC Class A Digital Device VCCI Class A EN60950 1 EN50371 EN55022 Class A EN55024 ITE EN61000 3 2 61000 3 3 IEC60950 1 AS NZS CISPR22 EN55022 Class A JIS C 61000 3 2 Supplied accessories Screw 4 D sub 9 pin connecting cable 3 m 1 Terminal board socket 10 pin 1 Operating instructions 1 For detailed information please contact your nearest Sony office LKRL Z211 ...

Страница 16: ...w ratio 1 35 1 to 2 40 1 LKRL Z219 Zoom Lens Throw ratio 1 85 1 to 4 00 1 LKRL A001 Anamorphic Lens with Lens Changer Unit LKRI 003 Dual link HD DC SDI Input Board For information on using the LKRI 003 board please contact your nearest Sony office LKRL A002 LKRL A003 3D Projection Lens Unit Throw ratio of LKRL A002 1 1 to 1 9 side mask 1 4 to 2 5 top bottom mask Throw ratio of LKRL A003 1 9 to 4 0...