Warning/Error Messages
189
App
end
ix
e
s
0013
TELEFILE FMT
NG
Telefile format is
invalid in one or
more locations.
0014
TELEFILE RD
FAIL
Telefile read failure
occurred.
0015
TELEFILE WR
FAIL
Telefile write failure
occurred.
0016
TELEFILE WR
INHI
Attempt to record
was made when
entire Telefile is
write inhibited.
0017
NO TELEFILE
LABE
Telefile could not be
recognized.
001A
ACC OVERLOAD Power consumption
by connected
accessories has
exceeded the rated
limit. Make sure that
total power
consumption by
accessories does not
exceed 16 W.
001C
LENS POWER
OFF
Stop the power
supply to the LENS
connector.
001D
DC OUT POWER
OFF
Stop the power
supply to the DC
OUT connector.
001E
RM POWER OFF
Stop the power
supply to the
REMOTE connector.
001F
VF POWER OFF
Stop the power
supply to the VF
connector.
0020
VIDEO PLL
UNLCOK
The timing generator
PLL is not locked to
the reference video
signal.
0022
AUDIO PLL
UNLOCK
Audio clock
generator PLL is not
locked to reference
video signal.
0030
NO SDI INPUT
When the optional
HKSR-9001 is
installed, there is no
valid input to the
AUX IN connector.
Code
Message
Description
0031
SDI INPUT
UNLOCK
The phase of the
signal input to the
AUX IN connector
does not correspond
to the setting made
on the <GENLOCK>
page
of the Camera
>MAINTENANCE
menu. Check the
setting and the input
signal.
0032
INVALID SDI
DATA
Data of the signal
input to the AUX IN
connector is invalid.
0036
SDI FMT
MISMATCH
Format of signals
input to AUX IN
connector does not
match system setting.
0038
MARI RST
Abnormality such as
insecurity of
synchronization was
detected during
recording operation.
Check the recording.
0039
PIER RESET
This message
generates when a
tape recorded in a
format which the
current system
setting does not
support is played
back.
0050
NO PB RF
Playback head is not
reading digital data
from tape.
0051
BAD CH
CONDITION
Playback signal
quality is bad.
0056
PB SEG NG
Abnormal recording
was detected on the
tape being played
back. Confirm
whether there was an
abnormal operation
or instability in
power during
recording or power-
on/off.
0057
PB TR ID NG
Code