EDIT
RAMP
Auto
Spd2
When RAMP is set to “LINE”, “INV”, or “EVEN”, sets the
number of frames shot of the ramp start point or the number
of frames shot of the ramp end point (
1FRM/FPS
).
(This is the number of frames shot at the end point when the
number of frames shot of the start point was set with Auto
Spd1. Otherwise it is the number of frames shot of the start
point.)
Duration When RAMP is set to “LINE”, “INV”, “EVEN”, or
“USER”, specifies the time (seconds) from the start of the
ramp to its end.
0 to 30s (0s)
Load
Curve
When RAMP is set to “USER”, displays a list of files saved
to a “Memory Stick”.
Manu
Spd1
When RAMP is set to “MANU”, specifies the upper or
lower limit of the number of frames shot (
1FRM/FPS
).
Manu
Spd2
When RAMP is set to “MANU”, specifies the upper or
lower limit of the number of frames shot (
1FRM/FPS
).
(This is the lower limit when the upper limit was set with
Manu Spd1. Otherwise it is the upper limit.)
POWER
Settings to reduce power
consumption
LED
Controls the power indicator.
ON [On]:
Normally light.
LOW [Low]:
Slightly dim.
OFF [Off]:
Disable lighting.
TALLY
Controls the tally indicator.
ON [On]:
Normally light.
LOW [Low]:
Slightly dim.
OFF [Off]:
Disable lighting.