11
3-3. Display and operation during external control
You cannot use buttons on the front panel while you control with an external
computer. In this case, three indicators of PROGRAM, REMOTE/ID and LOCK at
DISPLAY mode indicator light up.
The number of the display indicates the current program number and each output
channel indicator indicates the output level.
3-4. To RECALL
RECALL of stored programs with the unit is as follows.
1
Press RECALL/ENTER button while PRO-
GRAM indicator lights up.
Then the currently set program number
flashes and each output channel indicator
turns to flash simultaneously, meaning that it
is ready for setting output status. (Program
will not be changed until step
3
.)
2
Select program number you want to RECALL
with UP or DOWN button.
Then program numbers which are possible to
RECALL flash in turn and each output
channel indicator flashes and indicates output
status of the selected program as well.
3
Press RECALL/ENTER button.
The program number will stop flashing and
each channel indicator switches to output level
indication.
LOCK
PROGRAM
OUTPUT STATUS
REMOTE / ID
RECALL
/ENTER
FLASHES
RECALL
/ENTER
UP
DOWN
FLASHES
FLASHES
Содержание SRP-F300
Страница 20: ...Printed in Japan ...