2-9 (E)
SRG-300SE/301SE
2-2. SY-437
Board
When replacing the SY-437 board, perform the following procedure.
Otherwise, a trouble such as being
unable to obtain the IP address in DHCP occurs, and this unit does not
operate normally.
.
Replacement of MAC address label (Section 2-2-2)
.
Confirmation of model name/MAC address and writing of serial number (Section 2-2-3)
.
Firmware version upgrade (Section 2-2-4)
If the version upgrade is not performed, this unit may not operate normally.
n
As for the SY-437 board, the parts to be replaced vary between SRG-300SE and SRG-301SE. Replace the
parts required for each model. (Refer to Section 5.)
2-2-1. Required Equipment/Tools
.
PC
t
For the operating environment, refer to “Required system configuration” in the User’s Guide
.
LAN cable
.
SDI monitor
t
Prepare the 3G-SDI compatible monitor.
Prepare the 3G-SDI level A mapping.
.
BNC cable
.
12 VDC power supply
.
Latest updating firmware
t
Japanese site: http://www.sony.jp/brc/support/
English site: https://pro.sony.com/bbsc/ssr/cat-camerasptz/
.
Latest SNC toolbox
.
MAC/Serial writing tool: J-7121-430-A
n
Install the SNC toolbox and MAC/Serial writing tool according to Section 2-1-2 in advance.
2-2-2. Replacement of MAC Address Label
Replace the MAC address label attached to this unit with the MAC address label supplied with the new
SY-437 board.
Содержание SRG-300SE
Страница 1: ...HD COLOR VIDEO CAMERA SRG 300SE SRG 301SE SERVICE MANUAL 1st Edition ...
Страница 6: ......
Страница 70: ......
Страница 74: ...5 2 SRG 300SE 301SE Cabinet Block 5 2 Exploded Views BTP 2 6 8 BTP 2 6 8 BTP 2 6 8 BTP 2 6 8 2 3 3 2 4 1 ...
Страница 83: ......
Страница 84: ...Sony Corporation SRG 300SE J SRG 300SE SY SRG 301SE CN J E 9 878 620 01 Printed in Japan 2014 11 32 2014 ...