11
4-2.
BASE UNIT TEST MODE B
Manual System Test Mode
[Start-up]
1. Set the DIAL MODE switch to T (TONE), and turn on the
power while pressing the HANDSET LOCATOR key.
2. Change the DIAL MODE switch from T (TONE) to P
(PULSE)
b
T (TONE), and release the HANDSET LOCATOR
key to start up.
3. The TEST MODE B state will be set.
4. In test mode idling B, pressing the HANDSET LOCATOR
key with the P (PULSE)/T (TONE) switch set to T (TONE) state
switches to BASE UNIT TEST MODE B-1.
[Stutter Tone Detection]
1. Monitors the stutter tone detection terminal IC501 pin
(∞
(Stutte_Det) at all times and lights the VMWI LED when 5
pulses are detected like in actual operations.
HANDSET
LOCATOR
button
pressing
count
Radio mode
1ch single carrier continuous transmission mode
(high power)
10ch single carrier continuous transmission mode
(high power)
20ch single carrier continuous transmission mode
(high power)
1ch continuous transmission mode
(high power)
1ch continuous transmission mode (middle power)
1ch continuous transmission mode (low power)
10ch continuous transmission mode (high power)
10ch continuous transmission mode
(middle power)
10ch continuous transmission mode (low power)
20ch continuous transmission mode (high power)
20ch continuous transmission mode
(middle power)
20ch continuous transmission mode (low power)
1ch continuous reception mode
10ch continuous reception mode
20ch continuous reception mode
Returns to BASE UNIT TEST MODE • IDLING B
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
*1 Radio block: TDD mode (master timing)
Audio block: Line speech status
*2 Radio block: Standby status
Audio block: Line open
DIAL MODE switch
T (TONE) side
P (PULSE) side
Idle status
Test Mode Idle B-1 *1
Test Mode Idle B-2 *2
4-2-1. BASE UNIT Test Mode B-1
1. In test mode idling B with the P (PULSE)/T (TONE) switch set
to the T (TONE) state, pressing the HANDSET LOCATOR key
changes the mode as shown below.
2. Setting the P (PULSE)/T (TONE) switch from T (TONE) to P
(PULSE) in BASE UNIT test mode B-1 any time also enables
the mode to be changed to BASE UNIT test mode idling B.
Note
: If the LEDs are lit due to the idling state test, clear all the
LEDs, and return to the idling state.
4-2-2. Ending the Base Unit Test Mode
1. To end the base unit test mode, turn off the power of the base
unit.
ANTENNA
Pickup coil
Frequency counter
Spec: 904.2 MHz ± 27KHz
[BASE UNIT carrier frequency measurement
[Single carrier 1CH continuous transmission]]
Setting: