– 16 –
U2001
C2017
C2015
C2016
– BASE MAIN BOARD
(SIDE A) –
3-2. BASE UNIT
1. Test Mode
Entry— Simultaneously press the “HANDSET LOCATOR” key and toggle the “DIAL MODE” switch. When in test mode, the “LINE” and
“CHARGE” LEDs will be light on.
Alternative entry— Write 99h into LSB of location 9 in EEPROM.
Exit— Remove the AC power adaptor.
Toggle TX power— DIAL MODE switch (S2001)
T (TONE) position : TX ON
P (PULSE) position : TX OFF
Increment RF channel— Press the “HANDSET LOCATOR” key.
2. Test Equipment Required and Connection
3. Verify Procedure
Item
Remark
18.4MHz Frequency Error
Connect the frequency counter to the test point J1, press “0” key to turn on the TX power. Then, check
the frequency ± 1 kHz. If the result is within ± 1 kHz, then no adjustment required. Otherwise, refer to
item 4. for Adjustment Procedure.
4. Adjustment Procedure
Item
Adjustment Element
Remark
18.4MHz Frequency Error
C2016
1. Remove C2017 from the BASE MAIN board.
2. Solder an 20PF chip capacitor C2016 (1-164-160-11) on the
BASE MAIN board (in parallel of C2015).
3. Connect the frequency counter to the test point J1. Adjust for 0 Hz ± 1 kHz.
J1
frequency
counter
– BASE MAIN BOARD
(SIDE B) –
– RF UNIT (BU) –
Содержание SPP-ID970 - Cordless Telephone
Страница 3: ... 3 SECTION 1 GENERAL This section is extracted from SPP ID970 s instruction manual ...
Страница 4: ... 4 ...
Страница 5: ... 5 ...
Страница 6: ... 6 ...
Страница 7: ... 7 ...
Страница 8: ... 8 ...
Страница 9: ... 9 ...
Страница 10: ... 10 ...
Страница 11: ... 11 ...
Страница 14: ... 14 2 LED board 1 BTP 3x12 1 BTP 3x12 2 BTP 3x12 lug 3 B 2x8 4 RF unit BU 2 5 RF UNIT BU 2 6 LED BOARD ...
Страница 23: ... 29 30 SPP ID970 ID971 4 7 SCHEMATIC DIAGRAM HANDSET SECTION Refer to page 31 for IC Block Diagram ...
Страница 40: ...SPP ID970 ID971 7 8 2 1 SCHEMATIC DIAGRAM BASE UNIT SECTION 1 2 Refer to page 2 for Note ...
Страница 41: ... 9 10 SPP ID970 ID971 2 2 SCHEMATIC DIAGRAM BASE UNIT SECTION 2 2 Refer to page 2 for Note ...