7-3
2-3. POWER SUPPLY CHECK
2-3-1. Output Voltage Check (PS-418 Board)
Mode
E-E
Measuring
Digital voltmeter
instrument
SW 5V check
Measurement
CN101 pin
1
point
Specified
5.3 ± 0.3 Vdc
value
D 6V check
Measurement
CN101 pin
5
, CN103 pin
7
point
Specified
5.9 ± 0.3 Vdc
value
+ F check
Measurement
CN101 between pin
6
to
8
point
Specified
4.6 ± 0.7 Vdc
value
DC –30V check
Measurement
CN101 pin
7
point
Specified
– 30 ± 3.0 Vdc
value
PS 13V check
Measurement
CN102 pin
1
,
2
point
Specified
13.2 ± 1.0 Vdc
value
MTR 12V check
Measurement
CN102 pin
3
,
4
point
Specified
12 ± 1.0 Vdc
value
SW 12V check
Measurement
CN102 pin
8
, CN103 pin
1
point
Specified
12 ± 0.5 Vdc
value
AU –13V check
Measurement
CN102 pin
9
point
Specified
– 13 ± 0.5 Vdc
value
SW –13V check
Measurement
CN103 pin
4
point
Specified
– 13 ± 0.5 Vdc
value
MTR 10V check
Measurement
CN103 pin
9
point
Specified
10 ± 1.0 Vdc
value
[Check Method]
1)
Check that each voltage satisfied the specified value.
Note :
AC input voltage = 240 ± 5 Vac
2-4. VIDEO-CD SYSTEM ADJUSTMENTS
• CD Block is basically to operate without adjustment.
Therefore, check each item in order given.
• Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
• Use an oscilloscope with more than 10M
Ω
impedance.
• Clean the object lens by an applicator with neutral detergent when
the signal level is low than specified value with the following
checks.
[Adjustment Sequence]
1)
S-Curve check
2)
RF level check
3)
E-F Balance (Traverse) check
4)
RF PLL Free-run Frequency check
5)
Clock Adjustment
2-4-1. S-Curve Check (BD-21 Board)
Signal
Reference disc
Measurement
+ : TP FE
point
– : TP VC
Measuring
Oscilloscope
instrument
Specified
S-curve is symmetrical between A and B.
value
[Check Method]
1)
Connect oscilloscope to test point TP (FE) on BD-21 board.
2)
Connect between test point TP (FEI) and TP (VC) by lead wire.
3)
Turned Power switch on.
4)
Put disc (YEDS-18) in and turned Power switch on again and
actuate the focus search. (actuate the focus search when disc
table is moving in and out.)
5)
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B.
And confirm peak to peak level within 3 ± 1 Vp-p.
6)
After check, remove the lead wire connected in step 2.
Note :
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Fig. 7-2-6.
symmetry
within 3
±
1 Vp-p
A
B
S-curve waveform
Содержание SLV-7700KME
Страница 8: ...1 1 SLV 7700KME 7700KML SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 ...
Страница 18: ...1 11 ...
Страница 19: ...1 12 ...
Страница 20: ...1 13 ...
Страница 21: ...1 14 ...
Страница 22: ...1 15 ...
Страница 23: ...1 16 ...
Страница 24: ...1 17 ...
Страница 25: ...1 18 ...
Страница 26: ...1 19 ...
Страница 27: ...1 20 ...
Страница 28: ...1 21 ...
Страница 29: ...1 22E ...
Страница 76: ...SLV 7700KME 7700KML 5 55 5 56 TU 168 TUNER SCHEMATIC DIAGRAM Ref No TU 168 Board 7 000 Series TUNER TU 168 ...