2-7
SEL85F14GM (FE 1.4 / 85 GM) (FE 85mm F1.4 GM)
1. When connecting the LF-2141 Flexible Board to the CL-1040 Board, attach it correctly as shown in the figure below.
Connector
LF-2141 Flexible Board
LF-2141 Flexible Board
CL-1040 Board
CL-1040 Board
OK
NG
LF-2141 Flexible Board
CL-1040 Board
2. When connecting the Flexible Board (Stator Assy B) to the CL-1040 Board, attach it correctly as shown in the figure below.
Connector
Flexible Board
(Stator Assy B)
CL-1040 Board
Flexible Board
(Stator Assy B)
Flexible Board
(Stator Assy B)
CL-1040 Board
OK
NG
CL-1040 Board
3. Match the holes and convex portion of the CL-1040 board and attach it to the Outer Assy Service (9139).
Install the Flexible Board (Stator Assy B) as shown in the figure below.
CL-1040 Board
Flexible Board (Stator Assy B)
Hole
Convex portion
Flexible Board
(Stator Assy B)
Adhesive bond (B-10):
J-6082-612-A
1. Pass the Main FPC Assy (9139) through the small hole of Outer Assy Service (9139).
2. Pass the Flexible Board (Stator Assy B) through the large hole of Outer Assy Service (9139).
3. Insert the connector portion of Main FPC Assy (9139) to the groove of Outer Assy Service (9139).
4. Tighten the four screws.
5. Apply the adhesive bond (B-10) to the screw head.
Outer Assy Service (9139)
Large hole
Small hole
Flexible Board
(Stator Assy B)
Connector portion
(Main FPC Assy (9139))
Main FPC Assy (9139)
Screw
Apply the adhesive
bond (B-10)
Groove