57
2-8-4. PD-126 Board, LCD Assembly
Procedure
1. Remove the two precision screws, and then remove the handle cabinet (horizontal).
2. Disconnect the harness from the connector (CN6003) on the IF-1346 board.
3. Disconnect the fine-wire coaxial cable from the connector (CN9003) on the IF-1346 board.
4. Remove the four precision screws, and then remove the panel block.
A
IF-1346 board
Arrow view A
CN6003
CN9003
Harness
Fine-wire coaxial cable
Precision screws
(P2 x 4)
Precision screws
(P2 x 4)
Panel block
Precision screws
(P2.6 x 5)
Handle cabinet (horizontal)
Handle assembly