PCM-D100
22
SECTION 3
TEST MODE
1. SETTING THE TEST MODE
Note:
Test mode is impossible when battery voltage is not enough. Do
work using the battery with suffi cient battery level.
Setting method:
1. Equip this unit with battery.
2. Slide the [POWER] switch in the direction of “ON” until the
window display appears.
POWER
3. While pressing the [F1] and [T-MARK] keys, slide the
[HOLD] switch in the direction of “ON” or “OFF” (Either
“ON” or “OFF” is OK).
F1
T-MARK
HOLD
4. While pressing the [F1] and [T-MARK] keys, slide the [HOLD]
switch in the direction opposite to that specifi ed in step 3.
5. While pressing the [F1] and [T-MARK] keys, slide the [HOLD]
switch in the direction opposite to that specifi ed in step 4.
6. The test mode menu is displayed, and enter the test mode. Re-
lease the [F1] and [T-MARK] keys.
(Displayed characters/values in the following fi gure are ex-
ample)
<Version>
<Sleep>
<Deep Sleep>
<Off Deep Sleep>
<Power Down>
LCD Display
R
/
r
/ [ENT]
B
2. RELEASING THE TEST MODE
Remove battery.
3. CONFIGURATION OF THE TEST MODE
[
v
] key
[
V
] key
J
j
k
K
START
After turn on the power, stop or sleep condition.
While pressing the [F1] and [T-MARK] keys,
slide the [HOLD] switch ON or OFF
(Either ON or OFF is OK).
Slide the [HOLD] switch.
Remove battery.
Slide the [HOLD] switch.
End of test mode.
Determine
using
[
N
]
key
Return using
[
x
STOP]
key
Version
Sleep
Deep Sleep
Off Deep Sleep
Power Down
LCD Offset
LCD/Led/Light
Log Output
SIN
Menu Init
Factory Ship
Sircs Check
Factory Ship
Version
Release the [F1] and [T-MARK] keys.
Initial state of test mode