2-5 (E)
NSS-S2
Ref. No. Address
Indication Name
Function
Normal state
color
(When connect to
the MPU-136 board)
D4502
(G-9)
Green
RAID_FPGA__STATUS1
Circuit board operation status. Blinks after
Blinking
the on-board MPU starts up and the ready
state is established.
D4503
(G-9)
Amber
RAID_FPGA__STATUS2
For design purpose
Lights on
D4504
(G-9)
Amber
RAID_FPGA__STATUS3
D4505
(G-9)
Blue
RAID_FPGA__STATUS4
D4506
(G-9)
Blue
RAID_FPGA__STATUS5
D4507
(G-9)
Blue
RAID_FPGA__STATUS6
D4508
(G-9)
Blue
RAID_FPGA__STATUS7
D4509
Side B
Green
RAID_FPGA__INITDONE
RAID FPGA output. Lights when the RAID
Lights on
(G-9)
FPGA configuration is complete.
D7001
(H-5)
Green
SAS1064_LSI1_ACTIVITY3
Lights off
D7002
(H-5)
Green
SAS1064_LSI1_ACTIVITY2
D7003
(H-5)
Green
SAS1064_LSI1_ACTIVITY1
D7004
(H-5)
Green
SAS1064_LSI1_ACTIVITY0
D7005
(H-5)
Green
SAS1064_LSI1_LIFEBEET
Blinks when SAS1064 LSI1 is ready to start
Blinking
operation.
D7006
(H-4)
Red
SAS1064_LSI1_FOULT3
Lights on
D7007
(H-4)
Red
SAS1064_LSI1_FOULT2
Lights on
D7008
(H-4)
Red
SAS1064_LSI1_FOULT1
Lights off
D7009
(H-4)
Red
SAS1064_LSI1_FOULT0
Lights off
D7501
(G-5)
Green
SAS1064_LSI2_ACTIVITY3
Lights off
D7502
(G-5)
Green
SAS1064_LSI2_ACTIVITY2
D7503
(G-5)
Green
SAS1064_LSI2_ACTIVITY1
D7504
(G-5)
Green
SAS1064_LSI2_ACTIVITY0
D7505
(G-5)
Green
SAS1064_LSI2_LIFEBEET
Blinks when SAS1064 LSI2 is ready to start
Blinking
operation.
D7506
(G-4)
Red
SAS1064_LSI2_FOULT3
Lights off
D7507
(G-4)
Red
SAS1064_LSI2_FOULT2
D7508
(G-4)
Red
SAS1064_LSI2_FOULT1
D7509
(G-4)
Red
SAS1064_LSI2_FOULT0
D8001
(H-3)
Red
SASX12_LSI1_FAULT11
Blinking
D8002
(H-3)
Red
SASX12_LSI1_FAULT10
Blinking
D8003
(H-3)
Red
SASX12_LSI1_FAULT9
Lights off
D8004
(H-3)
Red
SASX12_LSI1_FAULT8
Lights off
D8005
(H-3)
Red
SASX12_LSI1_FAULT7
Lights off
D8006
(H-3)
Red
SASX12_LSI1_FAULT6
Lights off
D8007
(H-3)
Red
SASX12_LSI1_FAULT5
Lights off
D8008
(H-3)
Red
SASX12_LSI1_FAULT4
Lights off
D8009
(H-3)
Red
SASX12_LSI1_FAULT3
Lights off
D8010
(H-3)
Red
SASX12_LSI1_FAULT2
Lights off
D8011
(J-3)
Red
SASX12_LSI1_FAULT1
Lights off
D8012
(J-3)
Red
SASX12_LSI1_FAULT0
Lights on
Blink when Port3 to 0 on the SAS1064 LSI1
side are accessing data (send or receive).
Light when Port3 to 0 on the SAS1064 LSI1
side are not connected, or no link is
established.
Blink when Port3 to 0 on the SAS1064 LSI2
side are accessing data (send or receive).
Light when Port3 to 0 on the SAS1064 LSI2
side are not connected, or no link is
established.
Light when Port11 to 0 on the SASX12 LSI1
side are not connected, or no link is
established.
Содержание NSS-S2
Страница 1: ...MEDIA STORAGE UNIT NSS S2 INSTALLATION MANUAL 1st Edition Revised 1 Serial No 10001 and Higher ...
Страница 6: ......
Страница 8: ......
Страница 38: ......
Страница 40: ...Printed in Japan Sony Corporation 2006 12 16 2005 NSS S2 SY J E 3 903 855 02 ...