2-4 (E)
NSS-S2
LEDs
Ref. No. Address
Indication Name
Function
Normal state
color
(When connect to
the MPU-136 board)
D1503
(A-3)
Red
+
12 V_IN_ERROR
Lights when the voltage immediately after the fuse Lights off
of
+
12V input from the power supply is lower than
the specified value.
D1504
(A-3)
Red
+
3.3 V_ERROR
Lights when the DD converter output voltage
Lights off
(
+
3.3 V) is lower than the specified value.
D1505
(A-3)
Red
+
3.3 V_FPGA_IO_
Lights when the output voltage (+3.3 V) after the
Lights off
ERROR
MAIN/BBU selection LSI is lower than the
specified value.
D1506
(A-3)
Red
+
1.5 V_FPGA_
Lights when the series regulator output voltage
Lights off
CORE_ERROR
(+1.5 V) is lower than the specified value.
D1507
(A-3)
Red
+
2.5 V_FPGA_DDR_
Lights when the DD converter output voltage
Lights off
ERROR
(+2.5 V) is lower than the specified value.
D1508
(A-3)
Red
+
1.25 V_FPGA_DDR_
Lights when the DD converter output voltage
Lights off
VTT_ERROR
(+1.25 V) is lower than the specified value.
D1509
(A-2)
Red
+
5.0 V_ERROR
Lights when the DD converter output voltage
Lights off
(+5.0 V) is lower than the specified value.
D1510
(A-2)
Red
+
1.2 V_SAS_CORE_
Lights when the DD converter output voltage
Lights off
ERROR
(+1.2 V) is lower than the specified value.
D1601
(A-2)
Blue
MPU_CLK0_BLINK
For checking the CLK0 signal input from the
Blinking
MPU-136 board. Blinks when a clock is input.
D1602
(A-2)
Blue
MPU_CLK1_BLINK
For checking the CLK1 signal input from the
Blinking
MPU-136 board. Blinks when a clock is input.
D1603
(A-2)
Blue
MPU_CLK2_BLINK/
For checking the CLK2 signal input and CFPGA
Blinking
CFPGA_LIFE_BEET
configuration completion.
Blinks when configuration is complete.
D2010
(F-1)
Red
HOT_PLUG_ERROR0
Lights when an error occurs on the channel 0
Lights off
side of HOT PLUG LSI.
D2304
(E-3)
Red
+
3.3 V/
+
1.2 V_SAS_
Lights when an error occurs in the DD converter
Lights off
CORE_DD CON_ERROR
LSI that gen3.3 V/+1.2 V.
D3201
(A-7)
Blue
ETHERNET_FAST0_
Lights when Fast Ethernet PHY establishes a link
Lights off
FULLDUPLEX
in Full Duplex.
D3202
(A-7)
Blue
ETHERNET_FAST0_
Lights when the link speed of Fast Ethernet PHY
Lights off
SPEED100
reaches 100M (100Base-TX).
D3203
(A-7)
Blue
ETHERNET_FAST0_
Blinks when Fast Ethernet PHY is accessing data
Lights off
ACTIVITY
(send or receive).
D3204
(A-7)
Blue
ETHERNET_FAST0_LINK
Lights when Fast Ethernet PHY establishes a link. Lights off
D3501
(C-9)
Red
FIBERCHANNEL_
Lights when the port 0 side of FibreChannel is not
Lights on
PORT0_FOULT
connected, or no link is established.
D3502
(C-9)
Green
FIBERCHANNEL_
Blinks when the port 0 side of FibreChannel is
Lights off
PORT0_ACTIVITY
accessing data (send or receive).
D3503
(D-9)
Red
FIBERCHANNEL_
Lights when the port 1 side of FibreChannel is not
Lights on
PORT1_FOULT
connected, or no link is established.
D3504
(D-9)
Green
FIBERCHANNEL_
Blinks when the port 1 side of FibreChannel is
Lights off
PRTR1_ACTIVITY
accessing data (send or receive).
D3505
(D-9)
Blue
FIBERCHANNEL_LSI_
Blinks when the FibreChannel LSI is ready to start Blinking
LIFEBEET
operation (or when an error code is output when
an error occurs).
D3507
(E-7)
Blue
FIBERCHANNEL_LSI_
For design purpose
Lights off
BLUELED
D4001
Side B
Green
IFPLD_CONFDONE
IFPLD output. Lights when the RAID FPGA data
Lights on
(G-8)
output is complete.
D4501
(G-9)
Green
RAID_FPGA__STATUS0
Circuit board operation status. When the two PU-
Lights on or off
124 boards are installed, the operation side lights
up and the backup side lights out.
Содержание NSS-S2
Страница 1: ...MEDIA STORAGE UNIT NSS S2 INSTALLATION MANUAL 1st Edition Revised 1 Serial No 10001 and Higher ...
Страница 6: ......
Страница 8: ......
Страница 38: ......
Страница 40: ...Printed in Japan Sony Corporation 2006 12 16 2005 NSS S2 SY J E 3 903 855 02 ...